Literature DB >> 23879723

The Influence of the Tolerance between Mechanical Components on the Accuracy of Implants Inserted with a Stereolithographic Surgical Guide: A Retrospective Clinical Study.

Michele Cassetta1, Alfonso Di Mambro1, Gianni Di Giorgio1, Luigi V Stefanelli1, Ersilia Barbato1.   

Abstract

BACKGROUND: The stereolithographic-guided surgery system involves a sequence of diagnostic and therapeutic events, and errors can arise at different stages. In these systems, one of the potentially clinically relevant errors may be the mechanical errors caused by the bur-guide gap due to the presence of a rotational allowance of the drills in the tubes.
PURPOSE: The purpose of this retrospective clinical study is to determine if it is possible to reduce the total error by limiting the tolerance among the mechanical components and to evaluate its clinical incidence.
MATERIALS AND METHODS: Sixty-six implants were inserted using the External Hex Safe® (Materialise Dental, Leuven, Belgium) system (Group A), and 71 implants were inserted using the same system with mechanical components modified to minimize the tolerance (Group B). Regarding only the angular deviation values, the t-test was used to determine the influence of reduced tolerance among the mechanical components on the accuracy values.
RESULTS: t-Test showed that there is a statistically significant better accuracy with the modified system (Group B).
CONCLUSIONS: Limiting the error that originates from mechanical components, total error could be statistically significantly reduced. Mechanical error is one of the most important source of error using External Hex Safe stereolithographic surgical guide.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  CAD/CAM technology; accuracy; clinical study; computer-assisted; flapless implant surgery; implant; implantology; retrospective; stereo lithography

Mesh:

Substances:

Year:  2013        PMID: 23879723     DOI: 10.1111/cid.12120

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  7 in total

1.  Comparison of Different Types of Static Computer-Guided Implant Surgery in Varying Bone Inclinations.

Authors:  Pisut Thangwarawut; Pokpong Amornvit; Dinesh Rokaya; Sirichai Kiattavorncharoen
Journal:  Materials (Basel)       Date:  2022-04-20       Impact factor: 3.748

2.  Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study.

Authors:  Du-Hyeong Lee; Seo-Young An; Min-Ho Hong; Kyoung-Bae Jeon; Kyu-Bok Lee
Journal:  J Adv Prosthodont       Date:  2016-06-17       Impact factor: 1.904

3.  CAD/CAM implant surgical guides: maximum errors in implant positioning attributable to the properties of the metal sleeve/osteotomy drill combination.

Authors:  Dimitrios Apostolakis; Georgios Kourakis
Journal:  Int J Implant Dent       Date:  2018-11-09

4.  Comparison of Implant Placement Accuracy in Healed and Fresh Extraction Sockets between Static and Dynamic Computer-Assisted Implant Surgery Navigation Systems: A Model-Based Evaluation.

Authors:  Miaozhen Wang; Xiaohui Rausch-Fan; Yalin Zhan; Huidan Shen; Feng Liu
Journal:  Materials (Basel)       Date:  2022-04-11       Impact factor: 3.748

5.  Precision and trueness of computer-assisted implant placement using static surgical guides with open and closed sleeves: An in vitro analysis.

Authors:  Arndt Guentsch; Hongseok An; Andrew R Dentino
Journal:  Clin Oral Implants Res       Date:  2022-02-19       Impact factor: 5.021

6.  Accelerating orthodontic tooth movement: A new, minimally-invasive corticotomy technique using a 3D-printed surgical template.

Authors:  M Cassetta; M Giansanti
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2016-07-01

7.  Stereolithographic Surgical Guide with a Combination of Tooth and Bone Support: Accuracy of Guided Implant Surgery in Distal Extension Situation.

Authors:  Chia-Cheng Lin; Masahiro Ishikawa; Takeo Maida; Hsin-Chung Cheng; Keng-Liang Ou; Takashi Nezu; Kazuhiko Endo
Journal:  J Clin Med       Date:  2020-03-05       Impact factor: 4.241

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.