Literature DB >> 23877176

Rapid and sensitive HILIC-MS/MS analysis of carnitine and acetylcarnitine in biological fluids.

Andrea C Isaguirre1, Roberto A Olsina, Luis D Martinez, Alicia V Lapierre, Soledad Cerutti.   

Abstract

Monitoring carnitine and acetylcarnitine levels in biological fluids is a powerful tool for diagnostic studies. Research has recently shown that the analysis of carnitine and related compounds in clinical samples can be accomplished by different analytical approaches. Because of the polar and ionic nature of the analytes and matrix complexity, accurate quantitation is a highly challenging task. Thus, sample processing factors, preparation/cleanup procedures, and chromatographic/ionization/detection parameters were evaluated. On the basis of the results obtained, a rapid, selective, sensitive method based on hydrophilic interaction liquid chromatography-tandem mass spectrometry for the analysis of carnitine and acetylcarnitine in serum and urine samples is proposed. The matrix effect was assessed. The proposed approach was validated, the limits of detection were in the nanomolar range, and carnitine and acetylcarnitine levels were found within the micromolar range in both types of sample.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23877176     DOI: 10.1007/s00216-013-7193-6

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  3 in total

1.  Integration of Metabolomics and Transcriptomics Reveals Major Metabolic Pathways and Potential Biomarker Involved in Prostate Cancer.

Authors:  Shancheng Ren; Yaping Shao; Xinjie Zhao; Christopher S Hong; Fubo Wang; Xin Lu; Jia Li; Guozhu Ye; Min Yan; Zhengping Zhuang; Chuanliang Xu; Guowang Xu; Yinghao Sun
Journal:  Mol Cell Proteomics       Date:  2015-11-06       Impact factor: 5.911

2.  Development and validation of an UHPLC-Orbitrap-HRMS method for rapid determination of endogenous L-carnitine in patients on hemodialysis/peritoneal dialysis and its application to promote rational drug use.

Authors:  Wen-Ting Jiang; Liu-Xing Tang; Jie Pan; Cun-Jin Su; Zhu Shen; Zhan-Hong Hu; Zhou-Bing Zhan; Ai-Ming Shi
Journal:  Ann Transl Med       Date:  2022-01

3.  Graphene-based biomimetic materials targeting urine metabolite as potential cancer biomarker: application over different conductive materials for potentiometric transduction.

Authors:  Liliana A A N A Truta; Nádia S Ferreira; M Goreti F Sales
Journal:  Electrochim Acta       Date:  2014-12-20       Impact factor: 6.901

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.