Literature DB >> 23877111

A semi-automated vascular access system for preclinical models.

B N Berry-Pusey1, Y C Chang, S W Prince, K Chu, J David, R Taschereau, R W Silverman, D Williams, W Ladno, D Stout, T C Tsao, A Chatziioannou.   

Abstract

Murine models are used extensively in biological and translational research. For many of these studies it is necessary to access the vasculature for the injection of biologically active agents. Among the possible methods for accessing the mouse vasculature, tail vein injections are a routine but critical step for many experimental protocols. To perform successful tail vein injections, a high skill set and experience is required, leaving most scientists ill-suited to perform this task. This can lead to a high variability between injections, which can impact experimental results. To allow more scientists to perform tail vein injections and to decrease the variability between injections, a vascular access system (VAS) that semi-automatically inserts a needle into the tail vein of a mouse was developed. The VAS uses near infrared light, image processing techniques, computer controlled motors, and a pressure feedback system to insert the needle and to validate its proper placement within the vein. The VAS was tested by injecting a commonly used radiolabeled probe (FDG) into the tail veins of five mice. These mice were then imaged using micro-positron emission tomography to measure the percentage of the injected probe remaining in the tail. These studies showed that, on average, the VAS leaves 3.4% of the injected probe in the tail. With these preliminary results, the VAS system demonstrates the potential for improving the accuracy of tail vein injections in mice.

Entities:  

Mesh:

Year:  2013        PMID: 23877111      PMCID: PMC4271828          DOI: 10.1088/0031-9155/58/16/5351

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

1.  The rise of the mouse, biomedicine's model mammal.

Authors:  D Malakoff
Journal:  Science       Date:  2000-04-14       Impact factor: 47.728

2.  AMIDE: a free software tool for multimodality medical image analysis.

Authors:  Andreas Markus Loening; Sanjiv Sam Gambhir
Journal:  Mol Imaging       Date:  2003-07       Impact factor: 4.488

3.  Imaging skin pathology with polarized light.

Authors:  Steven L Jacques; Jessica C Ramella-Roman; Ken Lee
Journal:  J Biomed Opt       Date:  2002-07       Impact factor: 3.170

4.  Method to quantify tail vein injection technique in small animals.

Authors:  Ernest V Groman; Christopher P Reinhardt
Journal:  Contemp Top Lab Anim Sci       Date:  2004-01

5.  Optical polarization imaging.

Authors:  S G Demos; R R Alfano
Journal:  Appl Opt       Date:  1997-01-01       Impact factor: 1.980

6.  Research agenda. Opportunities for research and NIH.

Authors:  Francis S Collins
Journal:  Science       Date:  2010-01-01       Impact factor: 47.728

7.  Polarized light examination and photography of the skin.

Authors:  R R Anderson
Journal:  Arch Dermatol       Date:  1991-07

8.  Evaluation of mouse tail-vein injections both qualitatively and quantitatively on small-animal PET tail scans.

Authors:  Douglass C Vines; David E Green; Gen Kudo; Harald Keller
Journal:  J Nucl Med Technol       Date:  2011-10-03

9.  Microfluidic device for robust generation of two-component liquid-in-air slugs with individually controlled composition.

Authors:  Kan Liu; Yi-Chun Chen; Hsian-Rong Tseng; Clifton Kwang-Fu Shen; R Michael van Dam
Journal:  Microfluid Nanofluidics       Date:  2010-04-22       Impact factor: 2.529

10.  Absence of arterial phenotype in mice with homozygous slc2A10 missense substitutions.

Authors:  B L Callewaert; B L Loeys; C Casteleyn; A Willaert; P Dewint; J De Backer; R Sedlmeier; P Simoens; A M De Paepe; P J Coucke
Journal:  Genesis       Date:  2008-08       Impact factor: 2.487

View more
  5 in total

1.  An Automated Mouse Tail Vascular Access System by Vision and Pressure Feedback.

Authors:  Yen-Chi Chang; Brittany Berry-Pusey; Rashid Yasin; Nam Vu; Brandon Maraglia; Arion X Chatziioannou; Tsu-Chin Tsao
Journal:  IEEE ASME Trans Mechatron       Date:  2014-10-16       Impact factor: 5.303

2.  Development of a modular fluorescence overlay tissue imaging system for wide-field intraoperative surgical guidance.

Authors:  John Quan Minh Nguyen; Melanie McWade; Giju Thomas; Bryce T Beddard; Jennifer L Herington; Bibhash C Paria; Herbert S Schwartz; Jennifer L Halpern; Ginger E Holt; Anita Mahadevan-Jansen
Journal:  J Med Imaging (Bellingham)       Date:  2018-03-02

3.  Design and Evaluation of a Robotic Device for Automated Tail Vein Cannulations in Rodent Models.

Authors:  Alex Fromholtz; Max L Balter; Alvin I Chen; Josh M Leipheimer; Anil Shrirao; Timothy J Maguire; Martin L Yarmush
Journal:  J Med Device       Date:  2017-10-16       Impact factor: 0.582

4.  ARAS: an automated radioactivity aliquoting system for dispensing solutions containing positron-emitting radioisotopes.

Authors:  Alex A Dooraghi; Lewis Carroll; Jeffrey Collins; R Michael van Dam; Arion F Chatziioannou
Journal:  EJNMMI Res       Date:  2016-03-09       Impact factor: 3.138

5.  Assessment of radiopharmaceutical retention for vascular access ports using positron emission tomography imaging.

Authors:  Michael S Gossman; Huaiyu Zheng; John G Evans; Junling Li; Chin K Ng
Journal:  J Appl Clin Med Phys       Date:  2017-10-05       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.