Literature DB >> 23873791

An investigation into the mechanical and aesthetic properties of new generation coated nickel-titanium wires in the as-received state and after clinical use.

T Gerard Bradley1, David W Berzins2, Nicholas Valeri2, Jessica Pruszynski3, Theodore Eliades4, Christos Katsaros5.   

Abstract

BACKGROUND/
OBJECTIVES: The purpose of this study was to compare the mechanical, structural, and aesthetic properties of two types of aesthetic coated nickel-titanium (NiTi) wires compared with comparable regular NiTi wires in the as-received state and after clinical use. MATERIALS/
METHODS: Sixty one subjects were randomly assigned to four groups (N = 61), two groups of coated wires and two groups of comparable, non-coated controls (n = 15/group). The period in the mouth ranged from 4 to 12 weeks after insertion. In total, 121 wires (61 retrieved and 60 as-received) were used in the study. The percentages of coating retention and loss were extrapolated from scans. A brief survey of five questions with three choices was given to all patients. Differential scanning calorimetry (DSC) and three-point bending tests were done on as-received and used wires.
RESULTS: The surface characterization by the percentage of resin remaining indicated that most wires in both test groups lost a significant amount of coating. A patient survey indicated that this was a noticeable feature for patients. DSC analysis of the wires indicated that the metallurgical properties of the coated wires were not similar to the uncoated wires in the as-received condition. Three-point bending results indicate a wide variation in test results with large standard deviations among all the groups. LIMITATIONS: The extent of coating loss requires investigating, as do the biological properties of the detached coating.
CONCLUSIONS: Both wires lost a significant amount of aesthetic coating after varying periods in the mouth. The metallurgical testing of these findings may indicate that these wires perform differently in the mouth.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23873791     DOI: 10.1093/ejo/cjt048

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  7 in total

1.  Effects of salivary pH on coating durability of two different aesthetic archwire coatings under a simulated intraoral environment.

Authors:  Youssef Chikh Abdulkader; Anis F Kamaruddin; Rabiatul Basria S M N Mydin
Journal:  Saudi Dent J       Date:  2019-10-15

2.  Effects of intraoral aging on surface properties of coated nickel-titanium archwires.

Authors:  Roberto Rongo; Gianluca Ametrano; Antonio Gloria; Gianrico Spagnuolo; Angela Galeotti; Sergio Paduano; Rosa Valletta; Vincenzo D'Antò
Journal:  Angle Orthod       Date:  2013-12-05       Impact factor: 2.079

3.  Load-deflection characteristics of coated and noncoated nickel-titanium wires in self-ligating brackets using a modified bending test: An in vitro study.

Authors:  Tripti Tikku; Rohit Khanna; Akhil Agarwal; Kamna Srivastava; Shashank Shekhar; Ivy Shukla
Journal:  Dent Res J (Isfahan)       Date:  2019 Jan-Feb

4.  Evaluating the Mechanical Properties of Zinc-Coated Stainless Steel Orthodontic Wires Using Physical Vapor Deposition.

Authors:  Maryam Karandish; Mahmoud Pakshir; Milad Moghimi; Dana Jafarpour
Journal:  Int J Dent       Date:  2021-05-03

5.  Influence of surface layer on mechanical and corrosion properties of nickel-titanium orthodontic wires.

Authors:  Višnja Katić; Helena Otmačić Curković; Damir Semenski; Gorana Baršić; Katarina Marušić; Stjepan Spalj
Journal:  Angle Orthod       Date:  2014-03-21       Impact factor: 2.079

6.  Surface Characteristics of Esthetic Nickel⁻Titanium and Beta-Titanium Orthodontic Archwires Produced by Plasma Electrolytic Oxidation (PEO)-Primary Results.

Authors:  Ole Jung; Jean-Philippe Becker; Ralf Smeets; Martin Gosau; Germain Becker; Bärbel Kahl-Nieke; Anne-Kathrin Jung; Max Heiland; Alexander Kopp; Mike Barbeck; Till Koehne
Journal:  Materials (Basel)       Date:  2019-04-30       Impact factor: 3.623

7.  Ion Release and Surface Changes of Nickel-Titanium Archwires Induced by Changes in the pH Value of the Saliva-Significance for Human Health Risk Assessment.

Authors:  Zana Jusufi Osmani; Borut Poljšak; Saša Zelenika; Ervin Kamenar; Kristina Marković; Marko Perčić; Višnja Katić
Journal:  Materials (Basel)       Date:  2022-03-08       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.