Literature DB >> 2387296

Evaluation of a new biphasic culture system for the recovery of mycobacteria.

T Giger1, H J Burkardt.   

Abstract

A newly developed biphasic culture system (MB-Check) for recovery of mycobacteria was evaluated. The biphasic system consists of a bottle containing selective modified Middlebrook 7H9 broth and a mounted dip slide with chocolate agar and modified Middlebrook 7H11 agar with and without NAP. The system was compared with culture on two egg-based media, Lowenstein medium and a selective Gottsacker medium, using 995 routine specimens and 90 artificially seeded sputa. Mycobacterium tuberculosis was detected in 17 of the 995 routine specimens by the biphasic system and in 14 specimens by the egg-based media together. In the artificially seeded sputa the biphasic system showed higher sensitivity in detection of both tuberculosis complex and non-tuberculous mycobacteria than the egg-based media. The recovery times of the new system were comparable to those of the two conventional culture methods.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2387296     DOI: 10.1007/bf01979476

Source DB:  PubMed          Journal:  Eur J Clin Microbiol Infect Dis        ISSN: 0934-9723            Impact factor:   3.267


  10 in total

1.  DIFFERENTIATION OF MYCOBACTERIUM TUBERCULOSIS AND MYCOBACTERIUM BOVIS BY P-NITROBENZOIC ACID SYSCEPTIBILITY.

Authors:  M TSUKAMURA; S TSUKAMURA
Journal:  Tubercle       Date:  1964-03

2.  DIFFERENTIATION OF MYCOBACTERIA BY SUSCEPTIBILITY TO HYDROXYLAMINE AND 8-AZAGUANINE.

Authors:  M TSUKAMURA
Journal:  J Bacteriol       Date:  1965-08       Impact factor: 3.490

3.  Evaluation of the p-nitro-alpha-acetylamino-beta-hydroxypropiophenone differential test for identification of Mycobacterium tuberculosis complex.

Authors:  M A Morgan; K A Doerr; H O Hempel; N L Goodman; G D Roberts
Journal:  J Clin Microbiol       Date:  1985-04       Impact factor: 5.948

4.  Automatable radiometric detection of growth of Mycobacterium tuberculosis in selective media.

Authors:  G Middlebrook; Z Reggiardo; W D Tigertt
Journal:  Am Rev Respir Dis       Date:  1977-06

5.  Recovery and susceptibility testing of Mycobacterium tuberculosis from extrapulmonary specimens by the BACTEC radiometric method.

Authors:  G Fadda; S L Roe
Journal:  J Clin Microbiol       Date:  1984-05       Impact factor: 5.948

6.  Rapid recovery of mycobacteria from clinical specimens using automated radiometric technic.

Authors:  C H Park; D L Hixon; C B Ferguson; S L Hall; C C Risheim; C B Cook
Journal:  Am J Clin Pathol       Date:  1984-03       Impact factor: 2.493

7.  Evaluation of the BACTEC radiometric method for recovery of mycobacteria and drug susceptibility testing of Mycobacterium tuberculosis from acid-fast smear-positive specimens.

Authors:  G D Roberts; N L Goodman; L Heifets; H W Larsh; T H Lindner; J K McClatchy; M R McGinnis; S H Siddiqi; P Wright
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

8.  Comparison of a radiometric method (BACTEC) and conventional culture media for recovery of mycobacteria from smear-negative specimens.

Authors:  M A Morgan; C D Horstmeier; D R DeYoung; G D Roberts
Journal:  J Clin Microbiol       Date:  1983-08       Impact factor: 5.948

9.  Detection and recovery of mycobacteria by a radiometric procedure.

Authors:  H Takahashi; V Foster
Journal:  J Clin Microbiol       Date:  1983-02       Impact factor: 5.948

10.  Improved detection times for Mycobacterium avium complex and Mycobacterium tuberculosis with the BACTEC radiometric system.

Authors:  J M Kirihara; S L Hillier; M B Coyle
Journal:  J Clin Microbiol       Date:  1985-11       Impact factor: 5.948

  10 in total
  5 in total

1.  Comparison of MB-Check, BACTEC, and egg-based media for recovery of mycobacteria.

Authors:  C Abe; S Hosojima; Y Fukasawa; Y Kazumi; M Takahashi; K Hirano; T Mori
Journal:  J Clin Microbiol       Date:  1992-04       Impact factor: 5.948

2.  Comparative evaluation of the MB-Check system for recovery of mycobacteria from clinical specimens.

Authors:  C Piersimoni; V Morbiducci; G De Sio; G Scalise
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1992-12       Impact factor: 3.267

3.  Comparison of fluorescent BACTEC 9000 MB system, Septi-Chek AFB system, and Lowenstein-Jensen medium for detection of mycobacteria.

Authors:  A J van Griethuysen; A R Jansz; A G Buiting
Journal:  J Clin Microbiol       Date:  1996-10       Impact factor: 5.948

4.  Multicentre evaluation of a biphasic culture system for recovery of mycobacteria from clinical specimens.

Authors:  E Tortoli; F Mandler; M Bartolucci; G Bertoli; D Costa; A Goglio; B Innocenti; C Lacchini; F Marchesani; C Passerini Tosi
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1993-06       Impact factor: 3.267

5.  Comparison of the Septi-Chek AFB and BACTEC systems and conventional culture for recovery of mycobacteria.

Authors:  D L Sewell; A L Rashad; W J Rourke; S L Poor; J A McCarthy; M A Pfaller
Journal:  J Clin Microbiol       Date:  1993-10       Impact factor: 5.948

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.