Literature DB >> 2386991

The areas ratio of normal arterial junctions and its implications in pulse wave reflections.

G L Papageorgiou1, B N Jones, V J Redding, N Hudson.   

Abstract

STUDY
OBJECTIVE: The aim of the study was to establish measurements for the area ratios of normal arterial junctions at various anatomical sites in order to estimate the significance of pulse wave reflections in the healthy arterial system.
DESIGN: Coronary cineangiograms were used for the coronary junctions measurements and routine arteriograms for the rest of the junctions studied. A pair of digital calipers served to take measurements at a distance of one vessel diameter from the junction centre.
MEASUREMENTS AND MAIN RESULTS: A bell shaped distribution of arterial area ratios was found with mean value for coronary bifurcations of 1.179 (95% confidence limits, 1.138-1.220). Slightly higher values were found for the higher order coronary junctions. Other junctions had similar area ratio values with the exception of the aortoiliac junctions where the area ratio was found 0.848 (0.775-0.920). Overall area ratio was 1.14 (1.113-1.167). Asymmetrical coronary bifurcations had higher area ratio than symmetrical ones (p less than 0.05).
CONCLUSIONS: In the majority of cases the area ratios are in close agreement with the theoretically predicted values for forward matched junctions. Minimal pulse wave reflections are therefore expected to arise from the junctions of a healthy arterial system. We therefore consider that, contrary to the established view, the presence of reflected waves in the central arterial system is a potential pathological phenomenon and not a characteristic of the healthy system. This may have important theoretical implications for the way hemodynamic findings are interpreted. Finally we suggest that arterial area ratio can be considered as another criterion of normality of arterial junctions in the interpretation of angiograms.

Mesh:

Year:  1990        PMID: 2386991     DOI: 10.1093/cvr/24.6.478

Source DB:  PubMed          Journal:  Cardiovasc Res        ISSN: 0008-6363            Impact factor:   10.787


  6 in total

1.  Pulsations with reflected boundary waves: a hydrodynamic reverse transport mechanism for perivascular drainage in the brain.

Authors:  M Coloma; J D Schaffer; R O Carare; P R Chiarot; P Huang
Journal:  J Math Biol       Date:  2016-01-04       Impact factor: 2.259

2.  Boundary waves in a microfluidic device as a model for intramural periarterial drainage.

Authors:  Mikhail Coloma; J David Schaffer; Peter Huang; Paul R Chiarot
Journal:  Biomicrofluidics       Date:  2019-03-08       Impact factor: 2.800

3.  Ultrasound detection of altered placental vascular morphology based on hemodynamic pulse wave reflection.

Authors:  Anum Rahman; Yu-Qing Zhou; Yohan Yee; Jun Dazai; Lindsay S Cahill; John Kingdom; Christopher K Macgowan; John G Sled
Journal:  Am J Physiol Heart Circ Physiol       Date:  2017-03-31       Impact factor: 4.733

Review 4.  An introduction to wave intensity analysis.

Authors:  Kim H Parker
Journal:  Med Biol Eng Comput       Date:  2009-02-11       Impact factor: 2.602

5.  Optimized design of an arterial network model reproduces characteristic central and peripheral haemodynamic waveform features of young adults.

Authors:  Avinash Kondiboyina; Hilary A Harrington; Joseph J Smolich; Michael M H Cheung; Jonathan P Mynard
Journal:  J Physiol       Date:  2022-08-02       Impact factor: 6.228

6.  Branching Pattern of the Cerebral Arterial Tree.

Authors:  Jasper H G Helthuis; Tristan P C van Doormaal; Berend Hillen; Ronald L A W Bleys; Anita A Harteveld; Jeroen Hendrikse; Annette van der Toorn; Mariana Brozici; Jaco J M Zwanenburg; Albert van der Zwan
Journal:  Anat Rec (Hoboken)       Date:  2018-12-05       Impact factor: 2.064

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.