Literature DB >> 23869372

Clinical performance and peri-implant parameters of 132 implants supporting locator-retained overdentures: a case series of 33 patients.

Matthias Troeltzsch1, Volker Troeltzsch, Alan H Brodine, Roland Frankenberger, Karl Messlinger, Markus Troeltzsch.   

Abstract

PURPOSE: The aim of this study was to assess the long-term reliability of Locator-retained mandibular or maxillary overdentures and to examine clinical and radiographic parameters of the supporting implants.
MATERIALS AND METHODS: The authors performed a retrospective analysis of a case series. After implant placement and a submerged healing phase of about 3 months, all implants were restored with Locator-retained overdentures. The follow-up examinations included the assessment of the Plaque Index (PI) and sulcus Bleeding Index (SBI) as well as peri-implant soft tissue parameters, such as bleeding on probing (BOP) and pocket probing depth (PPD). The mean marginal bone loss was measured on panoramic radiographs. The clinical performance of Locator components and the prosthetic restoration were evaluated. Descriptive statistics were computed. For statistical analysis, non-parametric and parametric tests with respect to the variable scale were used. The significance level was set as P ≤ .05.
RESULTS: The sample was composed of 33 patients (18 men, 15 women) with a mean age of 66.8 years who received 132 implants (84 in the anterior maxilla, 48 in the anterior mandible). After 32.9 months of follow-up, one maxillary implant was lost. All prosthetic restorations were still functionally in place at the last follow-up appointment with moderate prosthodontic maintenance effort. Clinical parameters and radiographs revealed healthy tissues around most implants.
CONCLUSION: Within the limitations of this study, it can be concluded that Locators are a predictable alternative for anchorage of mandibular and maxillary overdentures with good clinical performance of both the prosthetic restorations and the supporting implants.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23869372     DOI: 10.11607/jomi.3009

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  1 in total

1.  Implant-prosthetic rehabilitation after radiation treatment in head and neck cancer patients: a case-series report of outcome.

Authors:  Jasna Cotic; Jure Jamsek; Milan Kuhar; Natasa Ihan Hren; Andrej Kansky; Mutlu Özcan; Peter Jevnikar
Journal:  Radiol Oncol       Date:  2016-02-07       Impact factor: 2.991

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.