Literature DB >> 23869371

Long-term effect of overdenture bar design on peri-implant tissues.

Karl Martin Lehmann1, Peer W Kämmerer, Julia Karbach, Herbert Scheller, Bilal Al-Nawas, Wilfried Wagner.   

Abstract

PURPOSE: To evaluate factors promoting mucositis and peri-implantitis (plaque accumulation, poor peri-implant soft tissue health, bone loss) with regard to prosthetic attachment systems consisting of implant-supported bar-retained overdentures.
MATERIALS AND METHODS: Patients who received TiOblast implants to support overdentures retained by either (1) prefabricated bars with or without extensions or (2) cast bars were recalled and examined clinically and radiographically. Plaque Index (PI), Sulcus Bleeding Index (SBI), probing pocket depth (PPD), and peri-implant bone loss were measured. Peri-implant tissue health was assessed, and the presence of mucositis and peri-implantitis was recorded. One-way analysis of variance with the Bonferroni adjustment was used to compare groups (α = .05).
RESULTS: Five to 10 years after prosthetic loading, 107 patients who received 516 TiOblast implants were evaluated; 31 of these patients were treated with 131 implants to support bar-retained overdentures. PI, SBI, PPD, and pathologic bone loss were least common in the group with prefabricated bars, followed by the group with prefabricated bars with extensions, and were most common in the group with cast bars. Plaque accumulation and pathologic bone loss values were higher with implants that supported mandibular bar-retained overdentures than with those supporting maxillary bar-retained overdentures. However, these differences among attachment systems or between maxillary and mandibular implants were not significant (P > .05). Mucositis was observed in one implant in the group with prefabricated bars, four implants in the group with prefabricated bars with extensions, and four implants in the group with cast bars. Peri-implantitis was observed in one implant of the cast bar group.
CONCLUSIONS: Five to 10 years after prosthetic loading, no significant difference in PI, SBI, PPD, pathologic bone loss, or peri-implant tissue conditions among the different bar designs tested was observed.

Entities:  

Mesh:

Year:  2013        PMID: 23869371     DOI: 10.11607/jomi.2161

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  2 in total

1.  Maxillary overdentures supported by four splinted direct metal laser sintering implants: a 3-year prospective clinical study.

Authors:  Francesco Mangano; Fabrizia Luongo; Jamil Awad Shibli; Sukumaran Anil; Carlo Mangano
Journal:  Int J Dent       Date:  2014-12-14

2.  Clinical outcomes of implant-retained mandibular overdentures using the bar and magnetic attachment systems: an up to 5-year retrospective study.

Authors:  Huan Zhou; Yang Jiao; Chu-Fan Ma; Chao Wang; San-Jun Zhao; Min Tian; Franklin R Tay; Ji-Hua Chen
Journal:  Ann Transl Med       Date:  2020-11
  2 in total