Mitsunobu Kitamura1, Noritake Hata1, Tadateru Takayama2, Atsushi Hirayama2, Masashi Ogawa3, Akira Yamashina3, Hisaaki Mera4, Hideaki Yoshino4, Fumitaka Nakamura5, Yoshihiko Seino6. 1. Division of Intensive Care Unit, Nippon Medical School Chiba-Hokusoh Hospital, Chiba, Japan. 2. Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan. 3. Department of Cardiology, Tokyo Medical University, Tokyo, Japan. 4. Second Department of Internal Medicine, Kyorin University School of Medicine, Tokyo, Japan. 5. Third Department of Internal Medicine, Teikyo University Chiba Medical Center, Chiba, Japan. 6. Cardiovascular Center, Nippon Medical School Chiba-Hokusoh Hospital, Chiba, Japan. Electronic address: y-seino@nms.ac.jp.
Abstract
BACKGROUND AND PURPOSE: An early diagnosis is essential for therapeutic decision and risk stratification in patients with suspected acute myocardial infarction (AMI). We analyzed and compared the diagnostic value of high-sensitivity troponin T (hs-TnT) and other cardiac markers in patients with an initially negative troponin T test at presentation. METHODS AND SUBJECTS: The present study was a prospective, multicenter study including five participating emergency cardiovascular tertiary centers in Japan. From November 2009 through January 2011, patients with suspected AMI at the emergency room with an initial troponin T (c-TnT) test <100 ng/L were enrolled. RESULTS: A total of 85 patients were prospectively assigned from five participating emergency cardiovascular tertiary centers in Japan. The median time from the onset of chest pain to the T0 sampling was 165 min [IQR 120-180]. The final diagnoses according to the recent universal definition and other standard cut-off values were AMI in 47, unstable angina in 12, and non AMI in 38 patients. The overall ROC-AUC value of hs-TnT, c-TnT, creatine kinase MB, and heart-type fatty acid-binding protein were 0.810, 0.716, 0.782, and 0.880, respectively. The diagnostic sensitivity and negative predictive value of hs-TnT were both 100% for the patients admitted more than 120 min from the onset, however the specificity was limited for the whole time-windows (71%). The absolute value change of the hs-TnT from T0 to T3 sampling 3h later improved the ROC-AUC up to 0.972 and the specificity was 92% at 22 ng/L (ROC-optimized cut-off) and 100% at 105 ng/L (rule-in cut-off). CONCLUSIONS: The hs-TnT displayed 100% sensitivity and negative predictive value for the patients admitted more than 120 min from the onset, however the specificity was limited. The absolute change from T0 to T3 (22 ng/L) improved the total diagnostic performance.
BACKGROUND AND PURPOSE: An early diagnosis is essential for therapeutic decision and risk stratification in patients with suspected acute myocardial infarction (AMI). We analyzed and compared the diagnostic value of high-sensitivity troponin T (hs-TnT) and other cardiac markers in patients with an initially negative troponin T test at presentation. METHODS AND SUBJECTS: The present study was a prospective, multicenter study including five participating emergency cardiovascular tertiary centers in Japan. From November 2009 through January 2011, patients with suspected AMI at the emergency room with an initial troponin T (c-TnT) test <100 ng/L were enrolled. RESULTS: A total of 85 patients were prospectively assigned from five participating emergency cardiovascular tertiary centers in Japan. The median time from the onset of chest pain to the T0 sampling was 165 min [IQR 120-180]. The final diagnoses according to the recent universal definition and other standard cut-off values were AMI in 47, unstable angina in 12, and non AMI in 38 patients. The overall ROC-AUC value of hs-TnT, c-TnT, creatine kinase MB, and heart-type fatty acid-binding protein were 0.810, 0.716, 0.782, and 0.880, respectively. The diagnostic sensitivity and negative predictive value of hs-TnT were both 100% for the patients admitted more than 120 min from the onset, however the specificity was limited for the whole time-windows (71%). The absolute value change of the hs-TnT from T0 to T3 sampling 3h later improved the ROC-AUC up to 0.972 and the specificity was 92% at 22 ng/L (ROC-optimized cut-off) and 100% at 105 ng/L (rule-in cut-off). CONCLUSIONS: The hs-TnT displayed 100% sensitivity and negative predictive value for the patients admitted more than 120 min from the onset, however the specificity was limited. The absolute change from T0 to T3 (22 ng/L) improved the total diagnostic performance.
Authors: Anvesh Ravanavena; Chetna Ravindra; Emmanuelar O Igweonu-Nwakile; Safina Ali; Salomi Paul; Shreyas Yakkali; Sneha Teresa Selvin; Sonu Thomas; Viktoriya Bikeyeva; Ahmed Abdullah; Aleksandra Radivojevic; Anas A Abu Jad; Prachi Balani Journal: Cureus Date: 2022-07-28
Authors: Bradley W Ellis; George Ronan; Xiang Ren; Gokhan Bahcecioglu; Satyajyoti Senapati; David Anderson; Eileen Handberg; Keith L March; Hsueh-Chia Chang; Pinar Zorlutuna Journal: Small Date: 2022-06-07 Impact factor: 15.153
Authors: Harsh Goel; Joshua Melot; Matthew D Krinock; Ashish Kumar; Sunil K Nadar; Gregory Y H Lip Journal: Ann Med Date: 2020-08-04 Impact factor: 4.709
Authors: Dieter Fischer; Friederike Remberg; Dirk Böse; Michael Lichtenberg; Philipp Kümpers; Pia Lebiedz; Hermann-Joseph Pavenstädt; Johannes Waltenberger; Frank Breuckmann Journal: Eur J Med Res Date: 2016-03-17 Impact factor: 2.175