Literature DB >> 23866140

Comparing microbial water quality in an intermittent and continuous piped water supply.

Emily Kumpel1, Kara L Nelson.   

Abstract

Supplying piped water intermittently is a common practice throughout the world that increases the risk of microbial contamination through multiple mechanisms. Converting an intermittent supply to a continuous supply has the potential to improve the quality of water delivered to consumers. To understand the effects of this upgrade on water quality, we tested samples from reservoirs, consumer taps, and drinking water provided by households (e.g. from storage containers) from an intermittent and continuous supply in Hubli-Dharwad, India, over one year. Water samples were tested for total coliform, Escherichia coli, turbidity, free chlorine, and combined chlorine. While water quality was similar at service reservoirs supplying the continuous and intermittent sections of the network, indicator bacteria were detected more frequently and at higher concentrations in samples from taps supplied intermittently compared to those supplied continuously (p < 0.01). Detection of E. coli was rare in continuous supply, with 0.7% of tap samples positive compared to 31.7% of intermittent water supply tap samples positive for E. coli. In samples from both continuously and intermittently supplied taps, higher concentrations of total coliform were measured after rainfall events. While source water quality declined slightly during the rainy season, only tap water from intermittent supply had significantly more indicator bacteria throughout the rainy season compared to the dry season. Drinking water samples provided by households in both continuous and intermittent supplies had higher concentrations of indicator bacteria than samples collected directly from taps. Most households with continuous supply continued to store water for drinking, resulting in re-contamination, which may reduce the benefits to water quality of converting to continuous supply.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  24/7 water supply; Continuous water supply; India; Intermittent water supply; Water distribution system; Water quality

Mesh:

Substances:

Year:  2013        PMID: 23866140     DOI: 10.1016/j.watres.2013.05.058

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  28 in total

1.  Water-energy sustainability synergies and health benefits as means to motivate potable reuse of coalbed methane-produced waters.

Authors:  Udayan Singh; Lisa M Colosi
Journal:  Ambio       Date:  2018-09-14       Impact factor: 5.129

2.  Monitoring bacterial contamination of piped water supply in rural coastal Bangladesh.

Authors:  Md Sabbir Ahsan; Md Ali Akber; Md Atikul Islam; Md Pervez Kabir; Md Ikramul Hoque
Journal:  Environ Monit Assess       Date:  2017-10-31       Impact factor: 2.513

3.  Surveillance at Private Laboratories Identifies Small Outbreaks of Hepatitis E in Urban Bangladesh.

Authors:  Hossain M S Sazzad; Alain B Labrique; Chong-Gee Teo; Stephen P Luby; Emily S Gurley
Journal:  Am J Trop Med Hyg       Date:  2016-12-19       Impact factor: 2.345

4.  Factors Associated with Water Service Continuity for the Rural Populations of Bangladesh, Pakistan, Ethiopia, and Mozambique.

Authors:  Ryan M DuChanois; Elisabeth S Liddle; Richard A Fenner; Marc Jeuland; Barbara Evans; Oliver Cumming; Rashid U Zaman; Ana V Mujica-Pereira; Ian Ross; Matthew O Gribble; Joe Brown
Journal:  Environ Sci Technol       Date:  2019-04-04       Impact factor: 9.028

Review 5.  Urban informal settlements as hotspots of antimicrobial resistance and the need to curb environmental transmission.

Authors:  Maya L Nadimpalli; Sara J Marks; Maria Camila Montealegre; Robert H Gilman; Monica J Pajuelo; Mayuko Saito; Pablo Tsukayama; Sammy M Njenga; John Kiiru; Jenna Swarthout; Mohammad Aminul Islam; Timothy R Julian; Amy J Pickering
Journal:  Nat Microbiol       Date:  2020-05-25       Impact factor: 17.745

6.  Planning for climate change: The need for mechanistic systems-based approaches to study climate change impacts on diarrheal diseases.

Authors:  Jonathan E Mellor; Karen Levy; Julie Zimmerman; Mark Elliott; Jamie Bartram; Elizabeth Carlton; Thomas Clasen; Rebecca Dillingham; Joseph Eisenberg; Richard Guerrant; Daniele Lantagne; James Mihelcic; Kara Nelson
Journal:  Sci Total Environ       Date:  2016-01-19       Impact factor: 7.963

7.  Why "improved" water sources are not always safe.

Authors:  Ameer Shaheed; Jennifer Orgill; Maggie A Montgomery; Marc A Jeuland; Joe Brown
Journal:  Bull World Health Organ       Date:  2014-01-10       Impact factor: 9.408

8.  Effects of hydraulically disconnecting consumer pumps in an intermittent water supply.

Authors:  David D J Meyer; J Khari; Andrew J Whittle; Alexander H Slocum
Journal:  Water Res X       Date:  2021-06-18

9.  Upgrading a piped water supply from intermittent to continuous delivery and association with waterborne illness: a matched cohort study in urban India.

Authors:  Ayse Ercumen; Benjamin F Arnold; Emily Kumpel; Zachary Burt; Isha Ray; Kara Nelson; John M Colford
Journal:  PLoS Med       Date:  2015-10-27       Impact factor: 11.069

Review 10.  Fecal contamination of drinking-water in low- and middle-income countries: a systematic review and meta-analysis.

Authors:  Robert Bain; Ryan Cronk; Jim Wright; Hong Yang; Tom Slaymaker; Jamie Bartram
Journal:  PLoS Med       Date:  2014-05-06       Impact factor: 11.069

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.