Literature DB >> 23866123

Large-volume sample stacking for in vivo monitoring of trace levels of γ-aminobutyric acid, glycine and glutamate in microdialysates of periaqueductal gray matter by capillary electrophoresis with contactless conductivity detection.

Petr Tůma1, Magdaléna Šustková-Fišerová, František Opekar, Václav Pavlíček, Klára Málková.   

Abstract

A new variant of large-volume sample stacking injection (LVSS) was used in the capillary electrophoresis with capacitively coupled contactless conductivity detection (CE/C(4)D) determination of the neurotransmitters γ-aminobutyric acid (GABA), glycine (Gly) and glutamate (Glu) in microdialysates of periaqueductal gray matter (PAG). The separation capillary was filled to 98% from the injection side with a sample of microdialysate in acetonitrile. Simultaneously with turning on the separation voltage, the sample zone was forced out by the background electrolyte by increasing the pressure in the terminal capillary outlet vessel. As a consequence of the stacking effect, the analyte was concentrated from the large sample volume into a narrow zone at the sample/background electrolyte boundary close to the injection end of the capillary. Under these conditions, LOD values of 9, 10 and 15nM were determined in the model samples for GABA, Gly and Glu, respectively; RSD equalled 0.5% for the migration times and 1.0-1.9% for the peak areas, respectively. In analysis of microdialysates of PAG, LOD values of 29, 29 and 37nM were determined for GABA, Gly and Glu, respectively; RSD equalled 0.5-0.7% for the migration times and 2.6-8.2% for the peak areas, respectively. The determined basal levels of the neurotransmitters in PAG microdialysates are 0.08, 4.7 and 0.8μM for GABA, Gly and Glu, respectively. Carrageenan-induced hyperalgesia increases the Gly and Glu levels and reduces GABA in PAG microdialysate. Peroral administration of paracetamol in hyperalgesia effectively reduces the Gly value and has no effect on Glu and GABA.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Capillary electrophoresis; Contactless conductivity detection; Large volume sample stacking; Neurotransmitters; Pain

Mesh:

Substances:

Year:  2013        PMID: 23866123     DOI: 10.1016/j.chroma.2013.06.019

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  A reliable LC-MS/MS method for the quantification of natural amino acids in mouse plasma: Method validation and application to a study on amino acid dynamics during hepatocellular carcinoma progression.

Authors:  Zhenzhen Liu; Mei-Juan Tu; Chao Zhang; Joseph L Jilek; Qian-Yu Zhang; Ai-Ming Yu
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2019-06-02       Impact factor: 3.205

2.  Analytical Techniques in Neuroscience: Recent Advances in Imaging, Separation, and Electrochemical Methods.

Authors:  Mallikarjunarao Ganesana; Scott T Lee; Ying Wang; B Jill Venton
Journal:  Anal Chem       Date:  2016-11-22       Impact factor: 6.986

3.  Evaluation of a Portable Microchip Electrophoresis Fluorescence Detection System for the Analysis of Amino Acid Neurotransmitters in Brain Dialysis Samples.

Authors:  Nathan J Oborny; Elton E Melo Costa; Leena Suntornsuk; Fabiane C Abreu; Susan M Lunte
Journal:  Anal Sci       Date:  2016       Impact factor: 2.081

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.