| Literature DB >> 23864579 |
Jens Wendeborn1, Peter Donndorf, Bernd Westphal, Gustav Steinhoff.
Abstract
Transcatheter aortic valve implantation, as well as interventional mitral valve repair, offer reasonable therapeutic options for high-risk surgical patients. We report a rare case of early post-interventional aortic valve prosthesis migration to the left ventricular outflow tract, with paravalvular leakage and causing severe mitral valve regurgitation. Initial successful interventional mitral valve repair using a clipped edge-to-edge technique revealed, in a subsequent procedure, the recurrence of mitral valve regurgitation leading to progressive heart failure and necessitating subsequent surgical aortic and mitral valve replacement.Entities:
Keywords: Aortic valve replacement; MitraClip; Mitral valve replacement; Surgery; TAVI; Valve migration
Mesh:
Year: 2013 PMID: 23864579 PMCID: PMC3805202 DOI: 10.1093/icvts/ivt313
Source DB: PubMed Journal: Interact Cardiovasc Thorac Surg ISSN: 1569-9285