Literature DB >> 23863761

Real-time monitoring of HIFU treatment using pulse inversion.

Jae Hee Song1, Yangmo Yoo, Tai-Kyong Song, Jin Ho Chang.   

Abstract

Ultrasound (US) imaging is widely used for the real-time guidance of high-intensity focused ultrasound (HIFU) treatment at a relatively low cost. However, ultrasound image guided HIFU (USgHIFU) is limited in the real-time monitoring of HIFU treatment due to the large amplitude HIFU signals received by the US imaging transducer. The amplitude of the HIFU scattered signal is generally much higher than the amplitude of the pulse-echo signal received by the imaging transducer. This creates an interference pattern obscuring the image of the tissue. As such, it is difficult to monitor lesion location. This paper proposes a real-time monitoring method to be performed concurrently with the HIFU insonation, but without HIFU interference, which allows for the improvement of treatment accuracy and safety in USgHIFU. The proposed method utilizes the physical properties of pulse inversion which is capable of removing the fundamental and odd harmonic components of the HIFU interference. Therefore, it is possible to secure the desired spectral bandwidth used to construct US images for HIFU treatment monitoring. The performance of the proposed method was evaluated through experiments with both a bovine serum albumin phantom and a chicken breast. The results demonstrated that the proposed method is capable of providing interference-free US images, thus successfully allowing for US imaging during HIFU treatment.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23863761     DOI: 10.1088/0031-9155/58/15/5333

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Pulse inversion enhances the passive mapping of microbubble-based ultrasound therapy.

Authors:  Antonios N Pouliopoulos; Mark T Burgess; Elisa E Konofagou
Journal:  Appl Phys Lett       Date:  2018-07-24       Impact factor: 3.791

Review 2.  Thermometry and ablation monitoring with ultrasound.

Authors:  Matthew A Lewis; Robert M Staruch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2015-03-10       Impact factor: 3.914

3.  FUS-Net: U-Net-Based FUS Interference Filtering.

Authors:  Stephen A Lee; Elisa E Konofagou
Journal:  IEEE Trans Med Imaging       Date:  2022-04-01       Impact factor: 10.048

4.  Using passive cavitation images to classify high-intensity focused ultrasound lesions.

Authors:  Kevin J Haworth; Vasant A Salgaonkar; Nicholas M Corregan; Christy K Holland; T Douglas Mast
Journal:  Ultrasound Med Biol       Date:  2015-06-04       Impact factor: 2.998

5.  Increased light penetration due to ultrasound-induced air bubbles in optical scattering media.

Authors:  Haemin Kim; Jin Ho Chang
Journal:  Sci Rep       Date:  2017-11-23       Impact factor: 4.379

6.  Design and Fabrication of Double-Focused Ultrasound Transducers to Achieve Tight Focusing.

Authors:  Jihun Jang; Jin Ho Chang
Journal:  Sensors (Basel)       Date:  2016-08-06       Impact factor: 3.576

7.  Real-Time Visualization of a Focused Ultrasound Beam Using Ultrasonic Backscatter.

Authors:  Miles Thies; Michael L Oelze
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-03-26       Impact factor: 2.725

  7 in total