Literature DB >> 23863718

Intra-patient semi-automated segmentation of the cervix-uterus in CT-images for adaptive radiotherapy of cervical cancer.

M Luiza Bondar1, Mischa Hoogeman, Wilco Schillemans, Ben Heijmen.   

Abstract

For online adaptive radiotherapy of cervical cancer, fast and accurate image segmentation is required to facilitate daily treatment adaptation. Our aim was twofold: (1) to test and compare three intra-patient automated segmentation methods for the cervix-uterus structure in CT-images and (2) to improve the segmentation accuracy by including prior knowledge on the daily bladder volume or on the daily coordinates of implanted fiducial markers. The tested methods were: shape deformation (SD) and atlas-based segmentation (ABAS) using two non-rigid registration methods: demons and a hierarchical algorithm. Tests on 102 CT-scans of 13 patients demonstrated that the segmentation accuracy significantly increased by including the bladder volume predicted with a simple 1D model based on a manually defined bladder top. Moreover, manually identified implanted fiducial markers significantly improved the accuracy of the SD method. For patients with large cervix-uterus volume regression, the use of CT-data acquired toward the end of the treatment was required to improve segmentation accuracy. Including prior knowledge, the segmentation results of SD (Dice similarity coefficient 85 ± 6%, error margin 2.2 ± 2.3 mm, average time around 1 min) and of ABAS using hierarchical non-rigid registration (Dice 82 ± 10%, error margin 3.1 ± 2.3 mm, average time around 30 s) support their use for image guided online adaptive radiotherapy of cervical cancer.

Entities:  

Mesh:

Year:  2013        PMID: 23863718     DOI: 10.1088/0031-9155/58/15/5317

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

Review 1.  Progress in Fully Automated Abdominal CT Interpretation.

Authors:  Ronald M Summers
Journal:  AJR Am J Roentgenol       Date:  2016-04-21       Impact factor: 3.959

Review 2.  Automated Radiation Treatment Planning for Cervical Cancer.

Authors:  Dong Joo Rhee; Anuja Jhingran; Kelly Kisling; Carlos Cardenas; Hannah Simonds; Laurence Court
Journal:  Semin Radiat Oncol       Date:  2020-10       Impact factor: 5.934

3.  Towards ultrasound-guided adaptive radiotherapy for cervical cancer: Evaluation of Elekta's semiautomated uterine segmentation method on 3D ultrasound images.

Authors:  Sarah A Mason; Tuathan P O'Shea; Ingrid M White; Susan Lalondrelle; Kate Downey; Mariwan Baker; Claus F Behrens; Jeffrey C Bamber; Emma J Harris
Journal:  Med Phys       Date:  2017-06-16       Impact factor: 4.071

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.