Acquisition technology research of EEG and related physiological signals under +Gz acceleration.

Y Li1, T Zhang, L Deng, B Wang.   

Abstract

BACKGROUND: With the continuous improvement of maneuvering performance of modern high-performance aircraft, the protection problem of flight personnel under high G acceleration, the development as well as research on monitoring system and the equipment for human physiological signals processing which include electroencephalogram (EEG) have become more and more important. Due to the particularity of +Gz experimental conditions, the high-risk of human experiments and the great difficulty of dynamic measurement, there is little research on the synchronous acquisition technology of EEG and related physiological signals under +Gz acceleration environment.
METHODS: We propose a framework to execute human experiments using the three-axial high-performance human centrifuge, develop reasonable operation mode and design a new experimental research method for EEG signal acquisition and variation characteristics on three-axial high-performance human centrifuge under the environment of +Gz acceleration. We also propose to build the synchronous real-time acquisition plan of EEG, electrocardiogram, brain blood pressure, ear pulse and related physiological signals under centrifuge +Gz acceleration with different equipments and methods.
RESULTS: The good profiles of EEG, heart rate, brain blood pressure and ear pulse are obtained and analyzed comparatively. In addition, the FMS hop-by-hop continuous blood pressure and hemodynamic measurement system Portapres are successfully applied to the ambulatory blood pressure measure under centrifuge +Gz acceleration environment.
CONCLUSIONS: The proposed methods establish the basis and have an important guiding significance for follow-up experiment development, EEG features spectral analysis and correlation research of all signals.

Entities:  

Mesh:

Year:  2013        PMID: 23860826     DOI: 10.1007/s11845-013-0988-9

Source DB:  PubMed          Journal:  Ir J Med Sci        ISSN: 0021-1265            Impact factor:   1.568


  12 in total

Review 1.  Mobile monitoring with wearable photoplethysmographic biosensors.

Authors:  H Harry Asada; Phillip Shaltis; Andrew Reisner; Sokwoo Rhee; Reginald C Hutchinson
Journal:  IEEE Eng Med Biol Mag       Date:  2003 May-Jun

2.  Performance of dry electrode with bristle in recording EEG rhythms across brain state changes.

Authors:  Vangu Kitoko; Tuan N Nguyen; Jordan S Nguyen; Yvonne Tran; Hung T Nguyen
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

3.  Technical quality evaluation of EEG recording based on electroencephalographers' knowledge.

Authors:  Masatoshi Nakamura; Qian Chen; Takenao Sugi; Akio Ikeda; Hiroshi Shibasaki
Journal:  Med Eng Phys       Date:  2005-01       Impact factor: 2.242

4.  Noninvasive measurement of instantaneous radial artery blood pressure. An instrument based on the volume-compensation method.

Authors:  Shinobu Tanaka; Shumei Gao; Masamichi Nogawa; Ken-ichi Yamakoshi
Journal:  IEEE Eng Med Biol Mag       Date:  2005 Jul-Aug

5.  Continuous noninvasive blood pressure measurement by pulse transit time.

Authors:  Parry Fung; Guy Dumont; Craig Ries; Chris Mott; Mark Ansermino
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

6.  A novel dry active electrode for EEG recording.

Authors:  C Fonseca; J P Silva Cunha; R E Martins; V M Ferreira; J P Marques de Sá; M A Barbosa; A Martins da Silva
Journal:  IEEE Trans Biomed Eng       Date:  2007-01       Impact factor: 4.538

7.  Adaptive hydrostatic blood pressure calibration: development of a wearable, autonomous pulse wave velocity blood pressure monitor.

Authors:  Devin B McCombie; Phillip A Shaltis; Andrew T Reisner; H Asada
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2007

8.  Multichannel Reflective PPG Earpiece Sensor With Passive Motion Cancellation.

Authors:  B P L Lo
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2007-12       Impact factor: 3.833

9.  Accuracy assessment of a noninvasive device for monitoring beat-by-beat blood pressure in the radial artery using the volume-compensation method.

Authors:  Shinobu Tanaka; Masamichi Nogawa; Takehiro Yamakoshi; Ken-Ichi Yamakoshi
Journal:  IEEE Trans Biomed Eng       Date:  2007-10       Impact factor: 4.538

10.  Wireless instrumentation system based on dry electrodes for acquiring EEG signals.

Authors:  Nuno Sérgio Dias; João Paulo Carmo; Paulo Mateus Mendes; José Higino Correia
Journal:  Med Eng Phys       Date:  2011-12-05       Impact factor: 2.242

View more
  2 in total

Review 1.  Categorisation of Mobile EEG: A Researcher's Perspective.

Authors:  Anthony D Bateson; Heidi A Baseler; Kevin S Paulson; Fayyaz Ahmed; Aziz U R Asghar
Journal:  Biomed Res Int       Date:  2017-12-04       Impact factor: 3.411

2.  Repeated positive acceleration exposure exacerbates endothelial dysfunction in high-fat-diet-induced hyperlipidemic rats.

Authors:  Zhihui Yang; Hua Ge; Chunya Wang; Zhongdong Li; Qingjun Zhang; Jianchang Wang
Journal:  Arch Med Sci       Date:  2017-06-12       Impact factor: 3.318

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.