Dosimetric consequences of prostate-based couch shifts on the precision of dose delivery during simultaneous IMRT irradiation of the prostate, seminal vesicles and pelvic lymph nodes.

Marta Adamczyk1, Tomasz Piotrowski2, Ewa Adamiak3, Julian Malicki2.   

Abstract

INTRODUCTION: To evaluate the impact interfraction prostate (CTV1) motion corrections on doses delivered to seminal vesicles (CTV2) and lymph nodes (CTV3), and to determine ideal planning target volume (PTV) margins for these targets with prostate-based position verification.
MATERIAL AND METHODS: Retrospective analysis based on 253 cone beam computed tomography (CBCT) studies of 28 patients. The isocenter-shift method was used to estimate the interfraction prostate and bony shift effects on the original plan coverage. Friedman's test was used to assess statistical significance between dose-volume histogram (DVH) parameters which were calculated for prostate-based sum plans, bony-based sum plans and original treatment plans. The van Herk formula was used to determine the set-up margin size for prostate-based verification.
RESULTS: The tracked shifts influenced the minimum, maximum and mean CTV2 and CTV3 doses, with a range differential of 0.17%-2.63% (prostate shifts) and 0.13%-1.92% (bony shifts) compared to the corresponding original parameters. Friedman's test revealed significant differences in the minimum doses to the CTV3 and maximum doses to both the CTV2 and CTV3. The calculated set-up margins of 1.22 cm (vertical), 0.19 cm (longitudinal) and 0.39 cm (lateral) should be added to CTV3 while performing prostate-based positioning.
CONCLUSION: To avoid geographical miss during simultaneous irradiation of independently moving targets (CTV1-3) appropriate margins should be used in accordance with the position verification method used. Based on our findings the following margin sizes should be used: 0.7 cm for the CTV1, 0.8-0.9 cm for the CTV2 , and asymmetric 1.0 cm (vertically) and 0.5 cm (other axes) for the CTV3.
Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  IGRT; IMRT; PTV expansion; Prostate cancer; Set-up error

Mesh:

Year:  2013        PMID: 23860339     DOI: 10.1016/j.ejmp.2013.06.003

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  7 in total

1.  Use of planar kV vs. CBCT in evaluation of setup errors in oesophagus carcinoma radiotherapy.

Authors:  Liliana Martins; Jose Guilherme Couto; Barbara Barbosa
Journal:  Rep Pract Oncol Radiother       Date:  2015-11-14

2.  Feasibility of intensity-modulated radiotherapy to treat gastric cancer.

Authors:  Agnieszka Skrobala; Marta Adamczyk; Aldona Karczewska-Dzionk
Journal:  Rep Pract Oncol Radiother       Date:  2018-11-16

Review 3.  Registration methods in radiotherapy.

Authors:  Paweł Czajkowski; Tomasz Piotrowski
Journal:  Rep Pract Oncol Radiother       Date:  2018-10-10

4.  Impact of rotational errors of whole pelvis on the dose of prostate-based image-guided radiotherapy to pelvic lymph nodes and small bowel in high-risk prostate cancer.

Authors:  Hiroki Katayama; Shigeo Takahashi; Takuya Kobata; Akihiro Oishi; Toru Shibata
Journal:  Rep Pract Oncol Radiother       Date:  2021-12-30

5.  Normal tissue sparing using different techniques for prostate irradiation.

Authors:  Barbara Melles-Bencsik; Tamás Pócza; Tibor Major; Péter Ágoston; Kliton Jorgo; Csaba Polgár; Csilla Pesznyák
Journal:  Rep Pract Oncol Radiother       Date:  2019-12-09

6.  Evaluating the accuracy of geometrical distortion correction of magnetic resonance images for use in intracranial brain tumor radiotherapy.

Authors:  Seyed Mehdi Bagherimofidi; Claus Chunli Yang; Roberto Rey-Dios; Madhava R Kanakamedala; Ali Fatemi
Journal:  Rep Pract Oncol Radiother       Date:  2019-10-19

Review 7.  ACR Appropriateness Criteria for external beam radiation therapy treatment planning for clinically localized prostate cancer, part II of II.

Authors:  Nicholas G Zaorsky; Timothy N Showalter; Gary A Ezzell; Paul L Nguyen; Dean G Assimos; Anthony V D'Amico; Alexander R Gottschalk; Gary S Gustafson; Sameer R Keole; Stanley L Liauw; Shane Lloyd; Patrick W McLaughlin; Benjamin Movsas; Bradley R Prestidge; Al V Taira; Neha Vapiwala; Brian J Davis
Journal:  Adv Radiat Oncol       Date:  2017-03-20
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.