Literature DB >> 23860133

Biomechanical evaluation of interlocking lag screw design in intramedullary nailing of unstable pertrochanteric fractures.

Stefanie Hoffmann1, Robert Paetzold, Daniel Stephan, Klaus Püschel, Volker Buehren, Peter Augat.   

Abstract

OBJECTIVES: Intramedullary nails with special lag screw designs may provide improved mechanical performance and alleviate clinical problems. We hypothesize that the proximal design of trochanteric nails affects mechanical performance.
METHODS: Ten pairs of human cadaveric femora were implanted with 2 different short intramedullary nails without (Gamma3) and with an interlocking lag screw (Intertan). An unstable, multifragmentary, pertrochanteric fracture was created. Bones were tested in a cyclic testing protocol with increasing loads until failure simulating 1 leg stance. Stiffness, failure load, cycles to failure, and fracture gap movements were measured.
RESULTS: Initially stiffness of the interlocking lag screw nail was almost 40% larger (P = 0.005) compared with the noninterlocking nail. During the test, the difference in stiffness gradually decreased. Failure load (13%, P = 0.02) and cycles to failure (18%, P = 0.02) were larger for the interlocking nail construct. Rotation and varus collapse of the head were initially up to 84% lower (P = 0.013) for the interlocking technique. During the test, the rate of rotational instability gradually increased for both techniques.
CONCLUSIONS: The interlocking lag screw design reduced movement of the femoral head and relative movement between fracture fragments. Beyond that the trapezoidal nail design of the Intertan reduced toggling within the trochanteric area and prolonged survival. Although this study showed a decrease in the retention of stability over time, failure did not occur until the equivalent of 2-3 months of reduced physical activity in which healing may have occurred under normal clinical conditions.

Entities:  

Mesh:

Year:  2013        PMID: 23860133     DOI: 10.1097/BOT.0b013e3182a1f54b

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  13 in total

Review 1.  Is rotation the mode of failure in pertrochanteric fractures fixed with nails? Theoretical approach and illustrative cases.

Authors:  C Kokoroghiannis; D Vasilakos; K Zisis; G Dimitriou; E Pappa; D Evangelopoulos
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-09-20

2.  Screw-blade fixation systems in Pauwels three femoral neck fractures: a biomechanical evaluation.

Authors:  Matthias Knobe; Simon Altgassen; Klaus-Jürgen Maier; Gertraud Gradl-Dietsch; Chris Kaczmarek; Sven Nebelung; Kajetan Klos; Bong-Sung Kim; Boyko Gueorguiev; Klemens Horst; Benjamin Buecking
Journal:  Int Orthop       Date:  2017-08-06       Impact factor: 3.075

3.  Intramedullary nailing in pertrochanteric fractures of the proximal femur.

Authors:  S J Ponce; M P Laird; J P Waddell
Journal:  Eur J Trauma Emerg Surg       Date:  2014-01-21       Impact factor: 3.693

4.  The visible and hidden blood loss of Asia proximal femoral nail anti-rotation and dynamic hip screw in the treatment of intertrochanteric fractures of elderly high- risk patients: a retrospective comparative study with a minimum 3 years of follow-up.

Authors:  Weiguang Yu; Xinchao Zhang; Rongbo Wu; Xingfei Zhu; Jun Hu; Yinfeng Xu; Jianhua Yi; Yunjiang Liu
Journal:  BMC Musculoskelet Disord       Date:  2016-07-11       Impact factor: 2.362

5.  Migration of the Lag Screw after Intramedullary Treatment of AO/OTA 31.A2.1-3 Pertrochanteric Fractures Does Not Result in Higher Incidence of Cut-Outs, Regardless of Which Implant Was Used: A Comparison of Gamma Nail with and without U-Blade (RC) Lag Screw and Proximal Femur Nail Antirotation (PFNA).

Authors:  Nikolaus Wilhelm Lang; Robert Breuer; Hannes Beiglboeck; Alexandru Munteanu; Stefan Hajdu; Reinhard Windhager; Harald Kurt Widhalm
Journal:  J Clin Med       Date:  2019-05-07       Impact factor: 4.241

6.  A retrospective analysis of the InterTan nail and proximal femoral nail anti-rotation-Asia in the treatment of unstable intertrochanteric femur fractures in the elderly.

Authors:  Weiguang Yu; Xinchao Zhang; Xingfei Zhu; Jun Hu; Yunjiang Liu
Journal:  J Orthop Surg Res       Date:  2016-01-15       Impact factor: 2.359

7.  Clinical analysis of peri-operative hidden blood loss of elderly patients with intertrochanteric fractures treated by unreamed proximal femoral nail anti-rotation.

Authors:  Bohua Li; Jun Li; Shanxi Wang; Lei Liu
Journal:  Sci Rep       Date:  2018-02-19       Impact factor: 4.379

8.  Proximal Femoral Nail Unlocked versus Locked (ProFNUL): a protocol for a multicentre, parallel-armed randomised controlled trial for the effect of femoral nail mode of lag screw locking and screw configuration in the treatment of intertrochanteric femur fractures.

Authors:  Arjun Sivakumar; Dominic Thewlis; Andreas Ladurner; Suzanne Edwards; Mark Rickman
Journal:  BMJ Open       Date:  2020-02-10       Impact factor: 2.692

Review 9.  Biomechanics of Osteoporotic Fracture Fixation.

Authors:  Marianne Hollensteiner; Sabrina Sandriesser; Emily Bliven; Christian von Rüden; Peter Augat
Journal:  Curr Osteoporos Rep       Date:  2019-12       Impact factor: 5.096

10.  Comparison of clinical outcomes with proximal femoral nail anti-rotation versus InterTAN nail for intertrochanteric femoral fractures: a meta-analysis.

Authors:  Wei Liu; Jie Liu; Guangrong Ji
Journal:  J Orthop Surg Res       Date:  2020-10-29       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.