Literature DB >> 23859608

Clinical applications and issues of oxygen saturation level measurements obtained from peripheral sites.

Jong Yong Abdiel Foo1, Kok Poo Chua, Xin Ji Alan Tan.   

Abstract

Studies have suggested that the saturated oxygen level within one's arterial blood can provide crucial information about the status of one's cardiopulmonary system. Currently, a popular and convenient approach is to obtain this vital physiological sign through non-invasive measurement on suitable peripheral sites such as a finger, toe or ear lobe. This measurement is known as the SpO2 parameter. It has been increasingly adopted in not only clinical settings but also remote monitoring purposes. In order to measure this optical based parameter, light sources of both the red and infrared wavelengths are required. The most recognized waveform feature is the peripheral pulse or its AC component which is synchronized to each heartbeat. The AC component is superimposed on a constant DC baseline attributed to breathing efforts, sympathetic nervous system activities and thermoregulation. The popularity of the SpO2 parameter may be due to its viable cost, simplicity to build and portability. Moreover, the basic building blocks of a SpO2 based measurement consists of control, filtering and amplification functions that can easily be incorporated with an embedded system. In this review, a brief description of the SpO2 measurement, its normative values and technical issues in its application as a clinical monitor are discussed.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23859608     DOI: 10.3109/03091902.2013.816380

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  5 in total

Review 1.  Limited Awareness of the Essences of Certification or Compliance Markings on Medical Devices.

Authors:  Jong Yong Abdiel Foo; Xin Ji Alan Tan
Journal:  Sci Eng Ethics       Date:  2016-11-28       Impact factor: 3.525

Review 2.  Intradialytic Hypoxemia in Chronic Hemodialysis Patients.

Authors:  Israel Campos; Lili Chan; Hanjie Zhang; Sheila Deziel; Cheryl Vaughn; Anna Meyring-Wösten; Peter Kotanko
Journal:  Blood Purif       Date:  2016-01-15       Impact factor: 2.614

3.  Hearables: New Perspectives and Pitfalls of In-Ear Devices for Physiological Monitoring. A Scoping Review.

Authors:  Michela Masè; Alessandro Micarelli; Giacomo Strapazzon
Journal:  Front Physiol       Date:  2020-10-16       Impact factor: 4.566

Review 4.  Contactless Vital Signs Monitoring From Videos Recorded With Digital Cameras: An Overview.

Authors:  Nunzia Molinaro; Emiliano Schena; Sergio Silvestri; Fabrizio Bonotti; Damiano Aguzzi; Erika Viola; Fabio Buccolini; Carlo Massaroni
Journal:  Front Physiol       Date:  2022-02-18       Impact factor: 4.566

5.  Ujuzi (Practical Pearl/Perle Pratique).

Authors:  P K Forson; M Osei-Ampofo; E K Acheampong; R Oteng; P Donkor; G Oduro
Journal:  Afr J Emerg Med       Date:  2014-08-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.