Integrity of the interface between denture base and soft liner: a scanning electron microscopic study.

G Muralidhar1, C L Satish Babu, Shilpa Shetty.   

Abstract

Aims and objectives of the study was to study the integrity of the interface between the denture base and the soft liner when the thickness of the soft liner was 0.5, 1.0 and 2.0 mm, and to study the integrity of the soft liner and denture base interface as influenced by aging process. 80 rectangular based specimens were fabricated using heat cured acrylic resin. The heat cured component of the specimen was fabricated from stainless steel template form by compression molding technique. Different thickness of silicone soft layer component was added to heat cured acrylic resin component of the specimen following the manufacturer's instructions to fabricate the group A, group B, group C and group D specimens. All the specimens were subjected to the same finishing and polishing procedures. The group A specimens was immediately scanned in scanning electron microscope after processing. A thermo statically controlled artificial saliva bath designed to maintain the temperature between 38 ± 4°C was used to simulate the oral condition and to age the group B, group C and group D specimens for 3 months after which they were subjected to scanning under a scanning electron microscope. All the aged specimens demonstrated two types of failures namely adhesive which occurred along the bond interface between the soft liner and the acrylic resin and adhesive and cohesive type of failure which occurred not only at the interface but also within the soft liner material itself. When the data was subjected to ANOVA, the group A specimens showed statistical significance with group B (P = 0.006), group C (P = 0.007) and group D specimens (P = 0.004), the level of significance being (P < 0.05). However, there was no statistical significance between group B and C (P = 0.98), group C and D specimens (P = 0.52), group B and D specimens (P = 0.70), the level of significance being (P < 0.05). Based on the results, statistical analysis of the results and within the limitations of this in vitro study the following conclusions can be drawn: The thickness of the liner did not show a statistically significant rate of failure on the integrity of the interface between the denture base resin and the soft liner and aging conditions simulating the clinical environment showed a statistically significant rate of failure on the integrity of the interface between the denture base resin and the soft liner.

Entities:  

Keywords:  Adhesive and cohesive failure; Aging the specimens; Failure at the interface; Integrity of the interface; Scanning electron microscope; Silicone soft liner; Study of the bond failure

Year:  2011        PMID: 23858278      PMCID: PMC3382366          DOI: 10.1007/s13191-011-0111-8

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


  8 in total

1.  Comparative study of water sorption, solubility, and tensile bond strength of two soft lining materials.

Authors:  A El-Hadary; J L Drummond
Journal:  J Prosthet Dent       Date:  2000-03       Impact factor: 3.426

2.  EVALUATION OF INDIRECT RESILIENT LINERS FOR DENTURES: LABORATORY AND CLINICAL TESTS.

Authors:  J F BATES; D C SMITH
Journal:  J Am Dent Assoc       Date:  1965-02       Impact factor: 3.634

3.  Properties of resilient denture liners.

Authors:  R G CRAIG; P GIBBONS
Journal:  J Am Dent Assoc       Date:  1961-09       Impact factor: 3.634

4.  The effects of surface machining on heat cured acrylic resin and two soft denture base materials: a scanning electron microscope and confocal microscope evaluation.

Authors:  D R Radford; T F Watson; J D Walter; S J Challacombe
Journal:  J Prosthet Dent       Date:  1997-08       Impact factor: 3.426

5.  The effect of finishing and polishing on surface roughness of a processed resilient denture liner.

Authors:  R W Loney; M B Moulding
Journal:  Int J Prosthodont       Date:  1993 Jul-Aug       Impact factor: 1.681

6.  Observations on long-term use of a soft-lining material for mandibular complete dentures.

Authors:  P S Wright
Journal:  J Prosthet Dent       Date:  1994-10       Impact factor: 3.426

7.  Effect of thermocycling on tensile bond strength of six silicone-based, resilient denture liners.

Authors:  Yasemin Kulak-Ozkan; Atilla Sertgoz; Hale Gedik
Journal:  J Prosthet Dent       Date:  2003-03       Impact factor: 3.426

8.  A prospective study on the clinical performance of polysiloxane soft liners: one-year results.

Authors:  Mustafa Murat Mutluay; Serra Oguz; Finn Fløystrand; Erik Saxegaard; Arife Dogan; Bulent Bek; I Eystein Ruyter
Journal:  Dent Mater J       Date:  2008-05       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.