Peritoneal dialysis catheter embedment: surgical considerations, expectations, and complications.

John H Crabtree1, Raoul J Burchette.   

Abstract

BACKGROUND: Peritoneal dialysis catheter embedment consists of implanting the catheter far in advance of anticipated need, with the external tubing buried under the skin. The catheter is externalized when initiation of dialysis is required. Details of the surgical procedure and management of associated complications are generally lacking.
METHODS: A total of 84 catheters including conventional and extended catheters were embedded and externalized during the study period. Factors influencing duration of embedment, functionality upon externalization, and long-term outcomes were analyzed.
RESULTS: Mean duration of embedment was 13.9 months (median 9.4; range .5 to 68.5). Immediate function was exhibited in 85.7% of catheters. Employing laparoscopic revision, 98.8% of embedded catheters were successfully used for peritoneal dialysis. Extended catheters and duration of embedment were important determinants of catheter functionality.
CONCLUSIONS: Catheters can be embedded for prolonged periods and still result in functional dialysis access when needed. Complications are few and easily managed.
Copyright © 2013 Elsevier Inc. All rights reserved.

Keywords:  Buried peritoneal dialysis catheter; Embedded peritoneal dialysis catheter; Extended peritoneal dialysis catheter; Moncrief-Popovich technique; Peritoneal dialysis; Peritoneal dialysis catheter

Mesh:

Year:  2013        PMID: 23856085     DOI: 10.1016/j.amjsurg.2013.03.006

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  3 in total

1.  Analysis of Hospitalization after Peritoneal Dialysis Catheter Implantation.

Authors:  Zi Li; Zita Abreu; Todd Penner; Lian He; Xihui Liu; Joanne M Bargman
Journal:  Perit Dial Int       Date:  2015-10-16       Impact factor: 1.756

2.  Embedded Catheters: Minimizing Excessive Embedment Time and Futile Placement while Maintaining Procedure Benefits.

Authors:  John H Crabtree; Raoul J Burchette; Rukhsana A Siddiqi
Journal:  Perit Dial Int       Date:  2014-10-07       Impact factor: 1.756

3.  Use of the embedded peritoneal dialysis catheter.

Authors:  S Sinha; M Fok; A Davenport; N Banga; B Lindsey; B Fernando; C J Forman
Journal:  Ann R Coll Surg Engl       Date:  2018-04-25       Impact factor: 1.891

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.