Literature DB >> 23853366

Low-power low-voltage current readout circuit for inductively powered implant system.

Mohammad R Haider, Syed K Islam, Salwa Mostafa.   

Abstract

Low voltage and low power are two key requirements for on-chip realization of wireless power and data telemetry for applications in biomedical sensor instrumentation. Batteryless operation and wireless telemetry facilitate robust, reliable, and longer lifetime of the implant unit. As an ongoing research work, this paper demonstrates a low-power low-voltage sensor readout circuit which could be easily powered up with an inductive link. This paper presents two versions of readout circuits that have been designed and fabricated in bulk complementary metal-oxide semiconductor (CMOS) processes. Either version can detect a sensor current in the range of 0.2 μA to 2 μA and generate square-wave data signal whose frequency is proportional to the sensor current. The first version of the circuit is fabricated in a 0.35-μ m CMOS process and it can generate an amplitude-shift-keying (ASK) signal while consuming 400 μ W of power with a 1.5-V power supply. Measurement results indicate that the ASK chip generates 76 Hz to 500 Hz frequency of a square-wave data signal for the specified sensor current range. The second version of the readout circuit is fabricated in a 0.5-μ m CMOS process and produces a frequency-shift-keying (FSK) signal while consuming 1.675 mW of power with a 2.5-V power supply. The generated data frequency from the FSK chip is 1 kHz and 9 kHz for the lowest and the highest sensor currents, respectively. Measurement results confirm the functionalities of both prototype schemes. The prototype circuit has potential applications in the monitoring of blood glucose level, lactate in the bloodstream, and pH or oxygen in a physiological system/environment.

Entities:  

Year:  2010        PMID: 23853366     DOI: 10.1109/TBCAS.2010.2042809

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  3 in total

1.  Analysis and optimization of spiral circular inductive coupling link for bio-implanted applications on air and within human tissue.

Authors:  Saad Mutashar; Mahammad A Hannan; Salina A Samad; Aini Hussain
Journal:  Sensors (Basel)       Date:  2014-06-30       Impact factor: 3.576

2.  Batteryless, Miniaturized Implantable Glucose Sensor Using a Fluorescent Hydrogel.

Authors:  Hyeonkeon Lee; Jongheon Lee; Honghyeon Park; Mi Song Nam; Yun Jung Heo; Sanghoek Kim
Journal:  Sensors (Basel)       Date:  2021-12-18       Impact factor: 3.576

Review 3.  Fully integrated biochip platforms for advanced healthcare.

Authors:  Sandro Carrara; Sara Ghoreishizadeh; Jacopo Olivo; Irene Taurino; Camilla Baj-Rossi; Andrea Cavallini; Maaike Op de Beeck; Catherine Dehollain; Wayne Burleson; Francis Gabriel Moussy; Anthony Guiseppi-Elie; Giovanni De Micheli
Journal:  Sensors (Basel)       Date:  2012-08-08       Impact factor: 3.576