Literature DB >> 23853278

A protein-based electrochemical biosensor array platform for integrated microsystems.

B L Hassler, R M Worden, A J Mason.   

Abstract

This paper elucidates challenges in integrating different classes of proteins into a microsystem and presents an electrochemical array strategy for heterogeneous protein-based biosensors. The overlapping requirements and limitations imposed by biointerface formation, electrochemical characterization, and microsystem fabrication are identified. A planar electrode array is presented that synergistically resolves these requirements using thin film Au and Ag/AgCl electrodes on a dielectric substrate. Using molecular self-assembly, electrodes were modified by nano-structures of two diverse proteins, alkali ion-channel protein and alcohol dehydrogenase enzyme. Electrochemical impedance spectroscopy and cyclic voltammetry measurements were performed to characterize sensor response to alkali ion and alcohol, respectively. This work demonstrates the viability of the electrochemical microsystem platform for heterogeneous protein-based biosensor interfaces.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23853278     DOI: 10.1109/TBCAS.2012.2195661

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833