Literature DB >> 23853203

An integrated patch-clamp potentiostat with electrode compensation.

P Weerakoon, E Culurciello, K G Klemic, F J Sigworth.   

Abstract

We present the first fully integrated implementation of a patch-clamp measurement system with series-access resistance and parasitic capacitive compensation capability. The system was implemented in a 0.5- mum silicon-on-sapphire process and is capable of recording cell membrane currents up to plusmn20 nA, with an rms noise of 5 pA at 10-kHz bandwidth. The system can compensate for the capacitance and resistance of the electrode, up to 20 pF and up to 70% of the series-access resistance, respectively. The die size is 1150 by 700 mum. The power consumption is 300 muW at 3.3 V. The integrated patch-clamp system will be used to fabricate high-throughput planar patch-clamp systems.

Entities:  

Year:  2009        PMID: 23853203     DOI: 10.1109/TBCAS.2008.2005419

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  7 in total

Review 1.  High bandwidth approaches in nanopore and ion channel recordings - A tutorial review.

Authors:  Andreas J W Hartel; Siddharth Shekar; Peijie Ong; Indra Schroeder; Gerhard Thiel; Kenneth L Shepard
Journal:  Anal Chim Acta       Date:  2019-01-25       Impact factor: 6.558

2.  Patch-clamp amplifiers on a chip.

Authors:  Pujitha Weerakoon; Eugenio Culurciello; Youshan Yang; Joseph Santos-Sacchi; Peter J Kindlmann; Fred J Sigworth
Journal:  J Neurosci Methods       Date:  2010-07-15       Impact factor: 2.390

3.  Ultracompact Microwatt CMOS Current Readout With Picoampere Noise and Kilohertz Bandwidth for Biosensor Arrays.

Authors:  Haitao Li; Sina Parsnejad; Ehsan Ashoori; Cort Thompson; Erin K Purcell; Andrew J Mason
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2017-10-05       Impact factor: 3.833

Review 4.  Recent advances in nanopore sequencing.

Authors:  Raj D Maitra; Jungsuk Kim; William B Dunbar
Journal:  Electrophoresis       Date:  2012-11-09       Impact factor: 3.535

Review 5.  The evolution of nanopore sequencing.

Authors:  Yue Wang; Qiuping Yang; Zhimin Wang
Journal:  Front Genet       Date:  2015-01-07       Impact factor: 4.599

Review 6.  CMOS Electrochemical Instrumentation for Biosensor Microsystems: A Review.

Authors:  Haitao Li; Xiaowen Liu; Lin Li; Xiaoyi Mu; Roman Genov; Andrew J Mason
Journal:  Sensors (Basel)       Date:  2016-12-31       Impact factor: 3.576

7.  Accounting for variability in ion current recordings using a mathematical model of artefacts in voltage-clamp experiments.

Authors:  Chon Lok Lei; Michael Clerx; Dominic G Whittaker; David J Gavaghan; Teun P de Boer; Gary R Mirams
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2020-05-25       Impact factor: 4.226

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.