| Literature DB >> 23852527 |
Rebecca Re1, Makii Muthalib2,3, Davide Contini4, Lucia Zucchelli4, Alessandro Torricelli4, Lorenzo Spinelli5, Matteo Caffini4,6, Marco Ferrari6, Valentina Quaresima6, Stephane Perrey7, Graham Kerr8.
Abstract
The application of different EMS current thresholds on muscle activates not only the muscle but also peripheral sensory axons that send proprioceptive and pain signals to the cerebral cortex. A 32-channel time-domain fNIRS instrument was employed to map regional cortical activities under varied EMS current intensities applied on the right wrist extensor muscle. Eight healthy volunteers underwent four EMS at different current thresholds based on their individual maximal tolerated intensity (MTI), i.e., 10 % < 50 % < 100 % < over 100 % MTI. Time courses of the absolute oxygenated and deoxygenated hemoglobin concentrations primarily over the bilateral sensorimotor cortical (SMC) regions were extrapolated, and cortical activation maps were determined by general linear model using the NIRS-SPM software. The stimulation-induced wrist extension paradigm significantly increased activation of the contralateral SMC region according to the EMS intensities, while the ipsilateral SMC region showed no significant changes. This could be due in part to a nociceptive response to the higher EMS current intensities and result also from increased sensorimotor integration in these cortical regions.Entities:
Mesh:
Substances:
Year: 2013 PMID: 23852527 DOI: 10.1007/978-1-4614-7411-1_59
Source DB: PubMed Journal: Adv Exp Med Biol ISSN: 0065-2598 Impact factor: 2.622