Literature DB >> 23852006

Mobile noncontact monitoring of heart and lung activity.

M Steffen, A Aleksandrowicz, S Leonhardt.   

Abstract

This paper describes two methods for noncontact monitoring of heart and lung activity, namely magnetic bioimpedance monitoring and capacitive electrocardiogram (ECG) recording. In principle, both methods bear the potential for mobile application in a personal healthcare scenario. To illustrate their performance, prototypes for both methods have been developed and first results are presented. Finally, the fundamental drawbacks and limitations of these methods are discussed, including a detailed stability analysis of the capacitively coupled ldquoright legrdquo in capacitive ECG measurements with mismatching electrode capacities and the development of an adaptive noise canceller for magnetic bioimpedance monitoring based on a nonlinear signal coupling model.

Year:  2007        PMID: 23852006     DOI: 10.1109/TBCAS.2008.915633

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  9 in total

1.  The Effect of Electrode Designs Based on the Anatomical Heart Location for the Non-Contact Heart Activity Measurement.

Authors:  Sun Ok Gi; Young-Jae Lee; Hye Ran Koo; Seung Pyo Lee; Kang-Hwi Lee; Kyeng-Nam Kim; Seung-Jin Kang; Joo Hyeon Lee; Jeong-Whan Lee
Journal:  J Med Syst       Date:  2015-10-21       Impact factor: 4.460

2.  First clinical evaluation of a novel capacitive ECG system in patients with acute myocardial infarction.

Authors:  Mareike B Weil; Martin Oehler; Meinhard Schilling; Lars S Maier
Journal:  Clin Res Cardiol       Date:  2011-11-08       Impact factor: 5.460

3.  Contact and Remote Breathing Rate Monitoring Techniques: A Review.

Authors:  Mohamed Ali; Ali Elsayed; Arnaldo Mendez; Yvon Savaria; Mohamad Sawan
Journal:  IEEE Sens J       Date:  2021-04-12       Impact factor: 4.325

4.  The MAIN Shirt: a textile-integrated magnetic induction sensor array.

Authors:  Daniel Teichmann; Andreas Kuhn; Steffen Leonhardt; Marian Walter
Journal:  Sensors (Basel)       Date:  2014-01-09       Impact factor: 3.576

Review 5.  Dry Electrodes for Human Bioelectrical Signal Monitoring.

Authors:  Yulin Fu; Jingjing Zhao; Ying Dong; Xiaohao Wang
Journal:  Sensors (Basel)       Date:  2020-06-29       Impact factor: 3.576

6.  A Wearable Capacitive Sensor Based on Ring/Disk-Shaped Electrode and Porous Dielectric for Noncontact Healthcare Monitoring.

Authors:  Ya-Nan Zheng; Zhe Yu; Guoyong Mao; Yunyao Li; Dhanapal Pravarthana; Waqas Asghar; Yiwei Liu; Shaoxing Qu; Jie Shang; Run-Wei Li
Journal:  Glob Chall       Date:  2020-03-18

7.  Detection of acute ventilatory problems via magnetic induction in a newborn animal model.

Authors:  Sabrina C Behr; Christopher Platen; Pascal Vetter; Nicole Heussen; Steffen Leonhardt; Thorsten Orlikowsky; Konrad Heimann
Journal:  Pediatr Res       Date:  2021-06-08       Impact factor: 3.953

8.  A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition.

Authors:  Ee-May Fong; Wan-Young Chung
Journal:  Sensors (Basel)       Date:  2015-08-05       Impact factor: 3.576

9.  An adaptive framework for real-time ECG transmission in mobile environments.

Authors:  Kyungtae Kang
Journal:  ScientificWorldJournal       Date:  2014-07-03
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.