Literature DB >> 23851472

Volumetric Flow Measurement Using an Implantable CMUT Array.

.   

Abstract

This paper describes volumetric-flow velocity measurement using an implantable capacitive micromachined ultrasonic transducer (CMUT) array. The array is comprised of multiple-concentric CMUT rings for ultrasound transmission and an outmost annular CMUT array for ultrasound reception. Microelectromechanical-system (MEMS) fabrication technology allows reception CMUT on this flowmeter to be implemented with a different membrane thickness and gap height than that of transmission CMUTs, optimizing the performance of these two different kinds of devices. The silicon substrate of this 2-mm-diameter CMUT ring array was bulk micromachined to approximately 80 to 100 μm thick, minimizing tissue disruption. The blood-flow velocity was detected using pulse ultrasound Doppler by comparing the demodulated echo ultrasound with the incident ultrasound. The demodulated ultrasound signal was sampled by a pulse delayed in time domain from the transmitted burst, which corresponds to detecting the signal at a specific distance. The flow tube/vessel diameter was detected through the time-flight delay difference from near and far wall reflections, which was measured from the ultrasound pulse echo. The angle between the ultrasound beam and the flow was found by using the cross-correlation from consecutive ultrasound echoes. Artificial blood flowing through three different polymer tubes was experimented with, while keeping the same volumetric flow rate. The discrepancy in flow measurement results between this CMUT meter and a calibrated laser Doppler flowmeter is less than 5%.

Entities:  

Year:  2011        PMID: 23851472     DOI: 10.1109/TBCAS.2010.2095848

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  3 in total

1.  Ultra-Low-Voltage Capacitive Micromachined Ultrasonic Transducers with Increased Output Pressure Due to Piston-Structured Plates.

Authors:  Fabian Merbeler; Sonja Wismath; Marco Haubold; Christian Bretthauer; Mario Kupnik
Journal:  Micromachines (Basel)       Date:  2022-04-26       Impact factor: 3.523

2.  Two Capacitive Micro-Machined Ultrasonic Transducers for Wind Speed Measurement.

Authors:  Gia Thinh Bui; Yu-Tsung Jiang; Da-Chen Pang
Journal:  Sensors (Basel)       Date:  2016-06-02       Impact factor: 3.576

3.  Design and Implementation of an Ultrasonic Flowmeter Based on the Cross-Correlation Method.

Authors:  Rui Ren; Hongliang Wang; Xiaolei Sun; He Quan
Journal:  Sensors (Basel)       Date:  2022-10-02       Impact factor: 3.847

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.