Literature DB >> 23850512

Feasibility study of patient positioning verification in electron beam radiotherapy with an electronic portal imaging device (EPID).

U Ramm1, J Köhn2, R Rodriguez Dominguez3, J Licher2, N Koch2, E Kara2, C Scherf2, C Rödel2, C Weiß2.   

Abstract

The purpose of this study is to demonstrate the feasibility of verification and documentation in electron beam radiotherapy using the photon contamination detected with an electronic portal imaging device. For investigation of electron beam verification with an EPID, the portal images are acquired irradiating two different tissue equivalent phantoms at different electron energies. Measurements were performed on an Elekta SL 25 linear accelerator with an amorphous-Si electronic portal imaging device (EPID: iViewGT, Elekta Oncology Systems, Crawley, UK). As a measure of EPID image quality contrast (CR) and signal-to-noise ratio (SNR) are determined. For characterisation of the imaging of the EPID RW3 slabs and a Gammex 467 phantom with different material inserts are used. With increasing electron energy the intensity of photon contamination increases, yielding an increasing signal-to-noise ratio, but images are showing a decreasing contrast. As the signal-to-noise ratio saturates with increasing dose a minimum of 50 MUs is recommended. Even image quality depends on electron energy and diameter of the patient, the acquired results are mostly sufficient to assess the accuracy of beam positioning. In general, the online EPID acquisition has been demonstrated to be an effective electron beam verification and documentation method. The results are showing that this procedure can be recommended to be routinely and reliably done in patient treatment with electron beams.
Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Electron; Electronic portal imaging device (EPID); Radiation; Radiotherapy; Verification

Mesh:

Year:  2013        PMID: 23850512     DOI: 10.1016/j.ejmp.2013.06.001

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  1 in total

1.  Treatment planning for spinal radiosurgery : A competitive multiplatform benchmark challenge.

Authors:  Christos Moustakis; Mark K H Chan; Jinkoo Kim; Joakim Nilsson; Alanah Bergman; Tewfik J Bichay; Isabel Palazon Cano; Savino Cilla; Francesco Deodato; Raffaela Doro; Jürgen Dunst; Hans Theodor Eich; Pierre Fau; Ming Fong; Uwe Haverkamp; Simon Heinze; Guido Hildebrandt; Detlef Imhoff; Erik de Klerck; Janett Köhn; Ulrike Lambrecht; Britta Loutfi-Krauss; Fatemeh Ebrahimi; Laura Masi; Alan H Mayville; Ante Mestrovic; Maaike Milder; Alessio G Morganti; Dirk Rades; Ulla Ramm; Claus Rödel; Frank-Andre Siebert; Wilhelm den Toom; Lei Wang; Stefan Wurster; Achim Schweikard; Scott G Soltys; Samuel Ryu; Oliver Blanck
Journal:  Strahlenther Onkol       Date:  2018-05-25       Impact factor: 3.621

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.