Literature DB >> 23850128

Mechanical comparison between lengthened and short sacroiliac screws in sacral fracture fixation: a finite element analysis.

Y Zhao1, S Zhang, T Sun, D Wang, W Lian, J Tan, D Zou, Y Zhao1.   

Abstract

OBJECTIVE: To compare the stability of lengthened sacroiliac screw and standard sacroiliac screw for the treatment of unilateral vertical sacral fractures; to provide reference for clinical applications.
METHODS: A finite element model of Tile type C pelvic ring injury (unilateral Denis type II fracture of the sacrum) was produced. The unilateral sacral fractures were fixed with lengthened sacroiliac screw and sacroiliac screw in six different types of models respectively. The translation and angle displacement of the superior surface of the sacrum (in standing position on both feet) were measured and compared.
RESULTS: The stability of one lengthened sacroiliac screw fixation in S1 or S2 segment is superior to that of one sacroiliac screw fixation in the same sacral segment. The stability of one lengthened sacroiliac screw fixation in S1 and S2 segments respectively is superior to that of one sacroiliac screw fixation in S1 and S2 segments respectively. The stability of one lengthened sacroiliac screw fixation in S1 and S2 segments respectively is superior to that of one lengthened sacroiliac screw fixation in S1 or S2 segment. The stability of one sacroiliac screw fixation in S1 and S2 segments respectively is markedly superior to that of one sacroiliac screw fixation in S1 or S2 segment. The vertical and rotational stability of lengthened sacroiliac screw fixation and sacroiliac screw fixation in S2 is superior to that of S1.
CONCLUSION: In a finite element model of type C pelvic ring disruption, S1 and S2 lengthened sacroiliac screws should be utilized for the fixation as regularly as possible and the most stable fixation is the combination of the lengthened sacroiliac screws of S1 and S2 segments. Even if lengthened sacroiliac screws cannot be systematically used due to specific conditions, one sacroiliac screw fixation in S1 and S2 segments respectively is recommended. No matter which kind of sacroiliac screw is used, if only one screw can be implanted, the fixation in S2 segment is more recommended than that in S1. LEVEL OF EVIDENCE: Experimental study Level III.
Copyright © 2013 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  3-Dimensional finite element; Pelvic ring disruption; Pelvis; Sacral fracture; Sacroiliac screw; Stability

Mesh:

Year:  2013        PMID: 23850128     DOI: 10.1016/j.otsr.2013.03.023

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  13 in total

1.  Influence of Different Boundary Conditions in Finite Element Analysis on Pelvic Biomechanical Load Transmission.

Authors:  Pan Hu; Tao Wu; Hui-Zhi Wang; Xin-Zheng Qi; Jie Yao; Xiao-Dong Cheng; Wei Chen; Ying-Ze Zhang
Journal:  Orthop Surg       Date:  2017-03-16       Impact factor: 2.071

2.  Do Transsacral-transiliac Screws Across Uninjured Sacroiliac Joints Affect Pain and Functional Outcomes in Trauma Patients?

Authors:  John Heydemann; Braden Hartline; Mary Elizabeth Gibson; Catherine G Ambrose; John W Munz; Matthew Galpin; Timothy S Achor; Joshua L Gary
Journal:  Clin Orthop Relat Res       Date:  2016-06       Impact factor: 4.176

Review 3.  Influence of double rods and interbody cages on range of motion and rod stress after spinopelvic instrumentation: a finite element study.

Authors:  Aleksander Leszczynski; Frank Meyer; Yann-Philippe Charles; Caroline Deck; Nicolas Bourdet; Rémy Willinger
Journal:  Eur Spine J       Date:  2022-04-23       Impact factor: 2.721

4.  Short-term outcome of fragility fractures of the pelvis in the elderly treated with screw osteosynthesis and external fixator.

Authors:  Konrad Schuetze; Alexander Eickhoff; Christoph Dehner; Alexander Blidon; Florian Gebhard; Peter Hinnerk Richter
Journal:  Eur J Trauma Emerg Surg       Date:  2021-09-21       Impact factor: 2.374

5.  Biomechanical comparison of three minimally invasive fixations for unilateral pubic rami fractures.

Authors:  Yong Zhao; Yupeng Ma; Dexin Zou; Xiujiang Sun; Gong Cheng; Wei Lian; Shengjie Dong; Yuchi Zhao; Wenqing Qu; Hao Wu
Journal:  BMC Musculoskelet Disord       Date:  2020-09-04       Impact factor: 2.362

6.  A useful intraoperative technique for transiliac-transsacral screws: a point-to-point coaxial guide apparatus.

Authors:  Ze-Hang Zheng; Fei Xu; Zheng-Qiang Luo; Ye Ren; Tao Fu; Han-Qing Xu; Bin-Bin Liu
Journal:  J Orthop Surg Res       Date:  2021-01-28       Impact factor: 2.359

7.  Biomechanical study of transsacral-transiliac screw fixation versus lumbopelvic fixation and bilateral triangular fixation for "H"- and "U"-type sacrum fractures with traumatic spondylopelvic dissociation: a finite element analysis study.

Authors:  Ye Peng; Gongzi Zhang; Shuwei Zhang; Xinran Ji; Junwei Li; Chengfei Du; Wen Zhao; Lihai Zhang
Journal:  J Orthop Surg Res       Date:  2021-07-03       Impact factor: 2.359

8.  Anatomical relation between S1 sacroiliac screws' entrance points and superior gluteal artery.

Authors:  Yong Zhao; Libo You; Wei Lian; Dexin Zou; Shengjie Dong; Tao Sun; Shudong Zhang; Dan Wang; Jingning Li; Wenliang Li; Yuchi Zhao
Journal:  J Orthop Surg Res       Date:  2018-01-18       Impact factor: 2.359

9.  The three-dimensional bone mass distribution of the posterior pelvic ring and its key role in transsacral screw placement.

Authors:  Darius M Thiesen; Dimitris Ntalos; Josephine Berger-Groch; Andreas Petersik; Bernhard Hofstätter; Karl-Heinz Frosch; Maximilian J Hartel
Journal:  Sci Rep       Date:  2020-03-30       Impact factor: 4.379

10.  Comparison of Biomechanical Characteristics and Pelvic Ring Stability Using Different Fixation Methods to Treat Pubic Symphysis Diastasis: A Finite Element Study.

Authors:  Feng Yao; Yu He; Hebu Qian; Dongsheng Zhou; Qinghu Li
Journal:  Medicine (Baltimore)       Date:  2015-12       Impact factor: 1.817

View more