Literature DB >> 23849734

Use of Kirschner wires with eyelets for tension band wiring of olecranon fractures.

Jin Young Kim1, Young Ho Lee, Hyun Sik Gong, Sang Lim Lee, Sang Ki Lee, Goo Hyun Baek.   

Abstract

PURPOSE: To evaluate the clinical and radiographic outcomes of tension band wiring of displaced olecranon fractures treated using Kirschner wires with eyelets to assess their clinical performance with respect to complications such as backing out of the K-wires, restriction of forearm rotation, and neurovascular injury.
METHODS: The authors retrospectively reviewed 44 patients treated for an isolated, displaced olecranon fracture and checked range of motion, postoperative pain, complications, and incidence of hardware removal. The mean follow-up period was 41 months (range, 26-73 mo).
RESULTS: All fractures united, and anatomical reduction was achieved in all cases at final follow-up. Mean elbow flexion was 135° (range, 115° to 140°), and mean elbow extension was 4° (range, 0° to 15°). No pin migration, restriction of forearm rotation, or neurovascular injury occurred. Hardware removal was performed in 8 cases (18%). Compared to previous results with conventional Kirschner wires, no meaningful improvement in postoperative pain level or in the rate of hardware removal was observed.
CONCLUSIONS: Tension band wiring using the pin studied produced excellent clinical and radiologic outcomes for the treatment of isolated, displaced Mayo type IIA and some type IIB olecranon fractures. The pin was effective in preventing the backing out of Kirschner wires and avoiding the complications associated with anterior cortical engagement of Kirschner wires, such as neurovascular injury or restriction of forearm rotation.
Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Neurovascular injury; olecranon fracture; pin migration; tension band pin system; tension band wiring

Mesh:

Year:  2013        PMID: 23849734     DOI: 10.1016/j.jhsa.2013.05.012

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  2 in total

1.  Surgical technique in tension band wiring method for selected comminuted olecranon fractures.

Authors:  Michio Okamoto; Jiro Namba; Kohji Kuriyama; Satoshi Miyamura; Hiroyuki Yokoi; Koji Yamamoto
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-09-20

2.  Factors Associated With Reoperation After Fixation of Displaced Olecranon Fractures.

Authors:  Femke M A P Claessen; Yvonne Braun; Rinne M Peters; George Dyer; Job N Doornberg; David Ring
Journal:  Clin Orthop Relat Res       Date:  2015-08-07       Impact factor: 4.176

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.