PURPOSE: The purpose of this investigation was to better understand lipid composition in human meibum. METHODS: Intact lipids in meibum samples were detected by direct infusion electrospray ionization mass spectrometry (ESI-MS) analysis in positive detection mode using sodium iodide (NaI) as an additive. The peak intensities of all major types of lipid species, that is, wax esters (WEs), cholesteryl esters (CEs), and diesters (DEs) were corrected for peak overlapping and isotopic distribution; an additional ionization efficiency correction was performed for WEs and CEs, which was simplified by the observation that the corresponding ionization efficiency was primarily dependent on the specific lipid class and saturation degree of the lipids while independent of the carbon chain length. A set of WE and CE standards was spiked in meibum samples for ionization efficiency determination and absolute quantitation. RESULTS: The absolute amount (μmol/mg) for each of 51 WEs and 31 CEs in meibum samples was determined. The summed masses for 51 WEs and 31 CEs accounted for 48 ± 4% and 40 ± 2%, respectively, of the total meibum lipids. The mass percentages of saturated and unsaturated species were determined to be 75 ± 2% and 25 ± 1% for CEs and 14 ± 1% and 86 ± 1% for WEs. The profiles for two types of DEs were also obtained, which include 42 α,ω Type II DEs, and 21 ω Type I-St DEs. CONCLUSIONS: Major neutral lipid classes in meibum samples were quantitatively profiled by ESI-MS analysis with NaI additive.
PURPOSE: The purpose of this investigation was to better understand lipid composition in human meibum. METHODS: Intact lipids in meibum samples were detected by direct infusion electrospray ionization mass spectrometry (ESI-MS) analysis in positive detection mode using sodium iodide (NaI) as an additive. The peak intensities of all major types of lipid species, that is, wax esters (WEs), cholesteryl esters (CEs), and diesters (DEs) were corrected for peak overlapping and isotopic distribution; an additional ionization efficiency correction was performed for WEs and CEs, which was simplified by the observation that the corresponding ionization efficiency was primarily dependent on the specific lipid class and saturation degree of the lipids while independent of the carbon chain length. A set of WE and CE standards was spiked in meibum samples for ionization efficiency determination and absolute quantitation. RESULTS: The absolute amount (μmol/mg) for each of 51 WEs and 31 CEs in meibum samples was determined. The summed masses for 51 WEs and 31 CEs accounted for 48 ± 4% and 40 ± 2%, respectively, of the total meibum lipids. The mass percentages of saturated and unsaturated species were determined to be 75 ± 2% and 25 ± 1% for CEs and 14 ± 1% and 86 ± 1% for WEs. The profiles for two types of DEs were also obtained, which include 42 α,ω Type II DEs, and 21 ω Type I-St DEs. CONCLUSIONS: Major neutral lipid classes in meibum samples were quantitatively profiled by ESI-MS analysis with NaI additive.
Entities:
Keywords:
mass spectrometry; neutral lipids; profiling; quantitation; sodium iodide
Authors: Rashmi K Shrestha; Douglas Borchman; Gary N Foulks; Marta C Yappert; Sarah E Milliner Journal: Invest Ophthalmol Vis Sci Date: 2011-09-21 Impact factor: 4.799
Authors: Robert C Murphy; Patrick F James; Andrew M McAnoy; Jessica Krank; Eva Duchoslav; Robert M Barkley Journal: Anal Biochem Date: 2007-03-18 Impact factor: 3.365
Authors: Alba Alfonso-García; Jerry Paugh; Marjan Farid; Sumit Garg; James V Jester; Eric O Potma Journal: J Raman Spectrosc Date: 2017-04-11 Impact factor: 3.133
Authors: Sarah E Hancock; Berwyck L J Poad; Mark D P Willcox; Stephen J Blanksby; Todd W Mitchell Journal: J Lipid Res Date: 2019-09-11 Impact factor: 5.922
Authors: Igor A Butovich; Hua Lu; Anne McMahon; Howard Ketelson; Michelle Senchyna; David Meadows; Elaine Campbell; Mike Molai; Emily Linsenbardt Journal: Invest Ophthalmol Vis Sci Date: 2014-01-07 Impact factor: 4.799