Wear analysis of 39 conserve plus metal-on-metal hip resurfacing retrievals.

Karren M Takamura1, Harlan C Amstutz1, Zhen Lu2, Pat A Campbell2, Edward Ebramzadeh2.   

Abstract

There have been increasing concerns regarding adverse local tissue reactions (ALTR) following metal-on-metal (MOM) hip arthroplasties. This study examined wear rates in retrievals of one design of MOM resurfacing arthroplasty, and assessed the differences in wear between those with and without ALTR. Wear measurements were made on 39 MOM resurfacing components (30 femoral, 9 acetabular) which were at least 2years in vivo. Seven hips (6 patients; 4 acetabular components, 7 femoral components) were identified to have ALTR. Acetabular component abduction and anteversion angles were determined using EBRA, and the contact-patch-to-rim (CPR) distance was calculated. The ALTR group had higher linear femoral and acetabular wear rates, acetabular anteversion and abduction angles, lower CPR, and longer time to revision. Given the increased risk for ALTR associated with acetabular component malpositioning, patients with malpositioned acetabular components may require closer clinical follow-up and monitoring.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  ALTR; arthroplasty; hip resurfacing; implant retrieval; metal-on-metal; wear

Mesh:

Substances:

Year:  2013        PMID: 23845764     DOI: 10.1016/j.arth.2013.05.032

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

Review 1.  Biotribology of artificial hip joints.

Authors:  Francesca Di Puccio; Lorenza Mattei
Journal:  World J Orthop       Date:  2015-01-18

2.  Outcomes after revision of metal on metal hip resurfacing to total arthroplasty using the direct anterior approach.

Authors:  Victoire Bouveau; Thomas-Xavier Haen; Joel Poupon; Christophe Nich
Journal:  Int Orthop       Date:  2018-03-08       Impact factor: 3.075

3.  Five Hundred Fifty-five Retrieved Metal-on-metal Hip Replacements of a Single Design Show a Wide Range of Wear, Surface Features, and Histopathologic Reactions.

Authors:  Sang-Hyun Park; Zhen Lu; Robert S Hastings; Patricia A Campbell; Edward Ebramzadeh
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

Review 4.  [Short hip stem for THA in avascular necrosis of the femoral head].

Authors:  F Thorey; T Floerkemeier; H Windhagen
Journal:  Orthopadie (Heidelb)       Date:  2022-09-07

Review 5.  Do retrieval analysis and blood metal measurements contribute to our understanding of adverse local tissue reactions?

Authors:  Patricia A Campbell; Michael S Kung; Andrew R Hsu; Joshua J Jacobs
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

6.  Surface Characterization of Retrieved Metal-on-Metal Total Hip Implants from Patients with Adverse Reaction to Metal Debris.

Authors:  Maria Burbano; Robert Russell; Michael Huo; Robert Welch; Diana Roy; Danieli C Rodrigues
Journal:  Materials (Basel)       Date:  2014-03-04       Impact factor: 3.623

  6 in total