Literature DB >> 23845500

Capillary isoelectric focusing of probiotic bacteria from cow's milk in tapered fused silica capillary with off-line matrix-assisted laser desorption/ionization time-of-flight mass spectrometry identification.

Marie Horká1, Pavel Karásek, Jiří Salplachta, Filip Růžička, Marie Vykydalová, Anna Kubesová, Vladimír Dráb, Michal Roth, Karel Slais.   

Abstract

In this study, combination of capillary isoelectric focusing (CIEF) in tapered fused silica (FS) capillary with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is presented as an efficient approach for unambiguous identification of probiotic bacteria in real sample. For this purpose, bacteria within genus Lactobacillus were selected as model bioanalytes and cow's milk was selected as a biological sample. CIEF analysis of both the cultivated bacteria and the bacteria in the milk was optimized and isoelectric points characterizing the examined bacteria were subsequently determined independently of the bacterial sample origin. The use of tapered FS capillary significantly enhanced the separation capacity and efficiency of the CIEF analyses performed. In addition, the cell number injected into the tapered FS capillary was quantified and an excellent linearity of the calibration curves was achieved which enabled quantitative analysis of the bacteria by CIEF with UV detection. The minimum detectable number of bacterial cells was 2×10(6) mL(-1). Finally, cow's milk spiked with the selected bacterium was analyzed by CIEF in tapered FS capillary, the focused and detected bacterial cells were collected from the capillary, deposited onto the cultivation medium, and identified using MALDI-TOF MS afterward. Our results have revealed that the proposed procedure can be advantageously used for unambiguous identification of probiotic bacteria in a real sample.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Capillary isoelectric focusing; Lactic acid bacteria; Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry; Milk; Tapered fused silica capillary

Mesh:

Year:  2013        PMID: 23845500     DOI: 10.1016/j.aca.2013.05.059

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  SDS-PAGE and Gel IEF: Tool for Differentiation of Methicillin-Resistant and Methicillin-Sensitive Strains of Staphylococcus aureus.

Authors:  Marie Tesařová; Marie Horká; Dana Moravcová; Lenka Svojanovská; Katarina Mlynarikova; Filip Růžička
Journal:  Curr Microbiol       Date:  2015-12-21       Impact factor: 2.188

2.  Nano-etched fused-silica capillary used for on-line preconcentration and electrophoretic separation of bacteriophages from large blood sample volumes with off-line MALDI-TOF mass spectrometry identification.

Authors:  Marie Horká; Pavel Karásek; Jiří Šalplachta; Filip Růžička; Dana Štveráková; Roman Pantůček; Michal Roth
Journal:  Mikrochim Acta       Date:  2020-02-19       Impact factor: 5.833

Review 3.  Emerging Options for the Diagnosis of Bacterial Infections and the Characterization of Antimicrobial Resistance.

Authors:  Simone Rentschler; Lars Kaiser; Hans-Peter Deigner
Journal:  Int J Mol Sci       Date:  2021-01-05       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.