Literature DB >> 23838879

Comparison of imaging methods used for dental implant osseous integration assessment.

C M Sprecher1, M Gahlert, S Röhling, H Kniha, B Gueorguiev, S Milz.   

Abstract

Two different imaging techniques used to determine bone tissue response to dental implants were compared. Dental implants were implanted into the maxillae of 18 pigs, which were sacrificed after 4, 8 and 12 weeks. Implants with surrounding bone tissue were retrieved for methyl methacrylate histology and contact radiography. On identical sections peri-implant bone density and bone implant contact (BIC) ratio were assessed with two different imaging methods. Evaluation of Giemsa eosin stained and contact radiographed sections showed direct osseous integration for all implants and both methods showed a strong correlation with correlation coefficient r = 0.930 (P < 0.0001) for peri-implant bone density and r = 0.817 (P < 0.0001) for bone implant contact ratio. While the two imaging methods showed moderate differences for peri-implant bone density there were significant differences between the BIC values determined. In general, contact radiography tends to underestimate BIC for approximately 4.5 % (P = 0.00003).

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23838879     DOI: 10.1007/s10856-013-4978-2

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  8 in total

1.  [ON THE HISTOLOGICAL PROCESSING OF UNDECALCIFIED BONE].

Authors:  R SCHENK
Journal:  Acta Anat (Basel)       Date:  1965

2.  Analysis of the influence of the macro- and microstructure of dental zirconium implants on osseointegration: a minipig study.

Authors:  Cornelia Katharina Mueller; Philipp Solcher; Andrè Peisker; Maia Mtsariashvilli; Karl Andreas Schlegel; Gerhard Hildebrand; Juergen Rost; Klaus Liefeith; Jiang Chen; Stefan Schultze-Mosgau
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2012-07-03

3.  Correlation between micro-computed tomography and histomorphometry for assessment of new bone formation in a calvarial experimental model.

Authors:  HeyRi Yeom; Steven Blanchard; Seokjin Kim; Susan Zunt; Tien-Min G Chu
Journal:  J Craniofac Surg       Date:  2008-03       Impact factor: 1.046

4.  Magnification rate of digital panoramic radiographs and its effectiveness for pre-operative assessment of dental implants.

Authors:  Y-K Kim; J-Y Park; S-G Kim; J-S Kim; J-D Kim
Journal:  Dentomaxillofac Radiol       Date:  2011-02       Impact factor: 2.419

5.  Bone feature analysis using image processing techniques.

Authors:  Z Q Liu; T Austin; C D Thomas; J G Clement
Journal:  Comput Biol Med       Date:  1996-01       Impact factor: 4.589

6.  Quantitative morphology of the subchondral plate of the tibial plateau.

Authors:  S Milz; R Putz
Journal:  J Anat       Date:  1994-08       Impact factor: 2.610

7.  In vivo performance of zirconia and titanium implants: a histomorphometric study in mini pig maxillae.

Authors:  M Gahlert; S Roehling; C M Sprecher; H Kniha; S Milz; K Bormann
Journal:  Clin Oral Implants Res       Date:  2011-08-02       Impact factor: 5.977

Review 8.  Are ceramic implants a viable alternative to titanium implants? A systematic literature review.

Authors:  Marina Andreiotelli; Hans J Wenz; Ralf-Joachim Kohal
Journal:  Clin Oral Implants Res       Date:  2009-09       Impact factor: 5.977

  8 in total
  1 in total

1.  In vivo and in vitro analysis in a rat model using zoledronate and alendronate medication: microbiological and scanning electron microscopy findings on peri-implant rat tissue.

Authors:  Ali Al-Ahmad; Ali Modabber; Kristian Kniha; Eva Miriam Buhl; Stephan Christian Möhlhenrich; Anna Bock; Frank Hölzle; Elmar Hellwig
Journal:  BMC Oral Health       Date:  2021-12-31       Impact factor: 2.757

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.