Literature DB >> 23836082

Peptide structural analysis using continuous Ar cluster and C60 ion beams.

Satoka Aoyagi1, John S Fletcher, Sadia Sheraz Rabbani, Tomoko Kawashima, Irma Berrueta Razo, Alex Henderson, Nicholas P Lockyer, John C Vickerman.   

Abstract

A novel application of time-of-flight secondary ion mass spectrometry (ToF-SIMS) with continuous Ar cluster beams to peptide analysis was investigated. In order to evaluate peptide structures, it is necessary to detect fragment ions related to multiple neighbouring amino acid residues. It is, however, difficult to detect these using conventional ToF-SIMS primary ion beams such as Bi cluster beams. Recently, C60 and Ar cluster ion beams have been introduced to ToF-SIMS as primary ion beams and are expected to generate larger secondary ions than conventional ones. In this study, two sets of model peptides have been studied: (des-Tyr)-Leu-enkephalin and (des-Tyr)-Met-enkephalin (molecular weights are approximately 400 Da), and [Asn(1) Val(5)]-angiotensin II and [Val(5)]-angiotensin I (molecular weights are approximately 1,000 Da) in order to evaluate the usefulness of the large cluster ion beams for peptide structural analysis. As a result, by using the Ar cluster beams, peptide molecular ions and large fragment ions, which are not easily detected using conventional ToF-SIMS primary ion beams such as Bi3 (+), are clearly detected. Since the large fragment ions indicating amino acid sequences of the peptides are detected by the large cluster beams, it is suggested that the Ar cluster and C60 ion beams are useful for peptide structural analysis.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23836082     DOI: 10.1007/s00216-013-7139-z

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  4 in total

1.  Lipid specific molecular ion emission as a function of the primary ion characteristics in TOF-SIMS.

Authors:  Kendra J Adams; John Daniel DeBord; Francisco Fernandez-Lima
Journal:  J Vac Sci Technol B Nanotechnol Microelectron       Date:  2016-08-24

2.  Molecular imaging of biological tissue using gas cluster ions.

Authors:  Hua Tian; Andreas Wucher; Nicholas Winograd
Journal:  Surf Interface Anal       Date:  2014-11       Impact factor: 1.607

3.  Gas Cluster Ion Beam Time-of-Flight Secondary Ion Mass Spectrometry High-Resolution Imaging of Cardiolipin Speciation in the Brain: Identification of Molecular Losses after Traumatic Injury.

Authors:  Hua Tian; Louis J Sparvero; Andrew A Amoscato; Anna Bloom; Hülya Bayır; Valerian E Kagan; Nicholas Winograd
Journal:  Anal Chem       Date:  2017-03-29       Impact factor: 6.986

4.  Mass spectrometric imaging of brain tissue by time-of-flight secondary ion mass spectrometry--How do polyatomic primary beams C₆₀⁺, Ar₂₀₀₀⁺, water-doped Ar₂₀₀₀⁺ and (H₂O)₆₀₀₀⁺ compare?

Authors:  Irma Berrueta Razo; Sadia née Rabbani Sheraz; Alex Henderson; Nicholas P Lockyer; John C Vickerman
Journal:  Rapid Commun Mass Spectrom       Date:  2015-10-30       Impact factor: 2.419

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.