ESR dosimetry of fossil enamel: some comments about measurement precision, long-term signal fading and dose-response curve fitting.

M Duval1, V Guilarte Moreno, R Grün.   

Abstract

This work deals with the specific studies of three main sources of uncertainty in electron spin resonance (ESR) dosimetry/dating of fossil tooth enamel: (1) the precision of the ESR measurements, (2) the long-term signal fading the selection of the fitting function. They show a different influence on the equivalent dose (D(E)) estimates. Repeated ESR measurements were performed on 17 different samples: results show a mean coefficient of variation of the ESR intensities of 1.20 ± 0.23 %, inducing a mean relative variability of 3.05 ± 2.29 % in the D(E) values. ESR signal fading over 5 y was also observed: its magnitude seems to be quite sample dependant but is nevertheless especially important for the most irradiated aliquots. This fading has an apparent random effect on the D(E) estimates. Finally, the authors provide new insights and recommendations about the fitting of ESR dose-response curves of fossil enamel with a double saturating exponential (DSE) function. The potential of a new variation of the DSE was also explored. Results of this study also show that the choice of the fitting function is of major importance, maybe more than the other sources previously mentioned, in order to get accurate final D(E) values.

Mesh:

Year:  2013        PMID: 23832975     DOI: 10.1093/rpd/nct167

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  1 in total

1.  Evaluating the Potential of Q-Band ESR Spectroscopy for Dose Reconstruction of Fossil Tooth Enamel.

Authors:  Verónica Guilarte; François Trompier; Mathieu Duval
Journal:  PLoS One       Date:  2016-03-01       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.