Literature DB >> 23831643

A dual-template imprinted polymer-modified carbon ceramic electrode for ultra trace simultaneous analysis of ascorbic acid and dopamine.

Bhim Bali Prasad1, Darshika Jauhari, Mahavir Prasad Tiwari.   

Abstract

A dual-template imprinted polymer film containing dispersed multiwalled carbon nanotubes was exploited in the fabrication of a typical, reproducible, and rugged carbon ceramic electrode, adopting "surface grafting from" approach for the growth of a nanometer thin coating on its surface. For this, chloro groups were first introduced at the exterior surface of silica-carbon composite electrode through sol-gel modification using (3-chloropropyl)-trimethoxysilane, followed by an iniferter (sodium diethyl dithiocarbamate) initiated photopolymerization of functional monomer (2,4,6-trisacrylamido-1,3,5-triazine), mixed templates (ascorbic acid and dopamine), and cross-linker (ethylene glycol dimethacrylate), in the presence of multiwalled carbon nanotubes. The modified sensor was validated for the simultaneous analysis of ascorbic acid and dopamine in aqueous, blood serum, cerebrospinal fluid, and pharmaceutical samples, using differential pulse anodic stripping voltammetric technique. The oxidation peak potentials for both analytes were found to be well apart approximately by 300 mV, which was large enough to allow selective and sensitive analysis of one in the presence of other, without any cross reactivity, interferences and false-positives. The detection limits realized by the proposed sensor, under optimized conditions, were found to be as low as 2.24 ng mL(-1) for ascorbic acid and 0.21 ng mL(-1) for dopamine (S/N=3). Such stringent limits could be considered suitable for the primitive diagnosis of several chronic diseases, in clinical settings.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Ascorbic acid; Carbon ceramic electrode; Differential pulse anodic stripping voltammetry; Dopamine; Dual template imprinted polymer film; Simultaneous ultra trace analysis

Mesh:

Substances:

Year:  2013        PMID: 23831643     DOI: 10.1016/j.bios.2013.05.062

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

Review 1.  Carbon Nanomaterial Based Biosensors for Non-Invasive Detection of Cancer and Disease Biomarkers for Clinical Diagnosis.

Authors:  Tibor Pasinszki; Melinda Krebsz; Thanh Tran Tung; Dusan Losic
Journal:  Sensors (Basel)       Date:  2017-08-20       Impact factor: 3.576

2.  Ultrasensitive and Highly Selective Electrochemical Detection of Dopamine Using Poly(ionic liquids)-Cobalt Polyoxometalate/CNT Composite.

Authors:  Neha Thakur; Subhasis Das Adhikary; Mukesh Kumar; Daisy Mehta; Anil K Padhan; Debaprasad Mandal; Tharamani C Nagaiah
Journal:  ACS Omega       Date:  2018-03-12

3.  Nanocomposite based on Poly (para-phenylene)/Chemical Reduced Graphene Oxide as a Platform for Simultaneous Detection of Ascorbic Acid, Dopamine and Uric Acid.

Authors:  Zouhour Hsine; Salma Bizid; Rym Milka; Hélène Sauriat-Dorizon; Ayoub Haj Said; Hafsa Korri-Youssoufi
Journal:  Sensors (Basel)       Date:  2020-02-25       Impact factor: 3.576

4.  Identification of volatile biomarkers of gastric cancer cells and ultrasensitive electrochemical detection based on sensing interface of Au-Ag alloy coated MWCNTs.

Authors:  Yixia Zhang; Guo Gao; Huijuan Liu; Hualin Fu; Jun Fan; Kan Wang; Yunsheng Chen; Baojie Li; Chunlei Zhang; Xiao Zhi; Lin He; Daxiang Cui
Journal:  Theranostics       Date:  2014-01-05       Impact factor: 11.556

  4 in total