Literature DB >> 23831000

Ultrasound-assisted dispersive liquid-liquid microextraction plus simultaneous silylation for rapid determination of salicylate and benzophenone-type ultraviolet filters in aqueous samples.

Jen-Wen Wu1, Hsin-Chang Chen, Wang-Hsien Ding.   

Abstract

A rapid procedure, using minimal amounts of solvent, for the reliable determination of five salicylate and benzophenone-type ultraviolet (UV) filters: ethylhexyl salicylate (EHS), 3,3,5-trimethyl-cyclohexyl salicylate (HMS), 2-hydroxy-4-methoxybenzophenone (BP-3), 2,4-dihydroxy-benzophenone (BP-1) and 2,2'-dihydroxy-4-methoxybenzophenone (BP-8), in aqueous samples is described. The method involves an ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) plus simultaneous silylation prior to their determination by gas chromatography-mass spectrometry (GC-MS). The parameters affecting the extraction and derivatization efficiency of the target UV filters from aqueous samples were systematically investigated and the conditions optimized. The optimal silylation and extraction conditions involved the rapid injection of a mixture of 750μL of acetone (as a dispersant), 15μL of tetrachloroethylene (as an extractant), and 20μL of BSTFA (as a derivatizing agent) into a 10-mL volume of aqueous samples (pH 7.0) containing 0.5g of sodium chloride in a glass tube with a conical bottom. After ultrasonication for 2.0min and centrifugation at 5000rpm (10min), the sedimented phase 5.0μL was directly introduced into the GC-MS. The limits of quantitation (LOQs) were less than 6ng/L. The precision for these analytes, as indicated by the relative standard deviations (RSDs), was less than 9% for both intra- and inter-day analysis. Accuracy, expressed as the mean extraction recovery, was between 74 and 92%. The method was then applied to environmental aqueous samples, using a standard addition method, showing the occurrence of BP-3 in samples of both river water and municipal wastewater treatment plant (MWTP) effluents.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  GC–MS; Organic UV filters; Simultaneous silylation; Ultrasound-assisted dispersive liquid–liquid microextraction; Water sample analysis

Mesh:

Substances:

Year:  2013        PMID: 23831000     DOI: 10.1016/j.chroma.2013.06.017

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  The occurrence of UV filters in natural and drinking water in São Paulo State (Brazil).

Authors:  Claudia Pereira da Silva; Elissandro Soares Emídio; Mary Rosa Rodrigues de Marchi
Journal:  Environ Sci Pollut Res Int       Date:  2015-08-18       Impact factor: 4.223

2.  Experimental design approaches to optimize ultrasound-assisted simultaneous-silylation dispersive liquid-liquid microextraction for the rapid determination of parabens in water samples.

Authors:  Chi-Zhong Hsieh; Wu-Hsun Chung; Wang-Hsien Ding
Journal:  RSC Adv       Date:  2021-07-06       Impact factor: 4.036

3.  Target, Suspect and Non-Target Screening of Silylated Derivatives of Polar Compounds Based on Single Ion Monitoring GC-MS.

Authors:  Bhekumuzi Prince Gumbi; Brenda Moodley; Grace Birungi; Patrick Gathura Ndungu
Journal:  Int J Environ Res Public Health       Date:  2019-10-21       Impact factor: 3.390

4.  Determination of Benzophenones in Water and Cosmetics Samples: A Comparison of Solid-Phase Extraction and Microextraction by Packed Sorbent Methods.

Authors:  Grażyna Wejnerowska; Izabela Narloch
Journal:  Molecules       Date:  2021-11-16       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.