Literature DB >> 23830365

Differences in aortic arch radius of curvature, neck size, and taper in patients with traumatic and aortic disease.

Hillary B Alberta1, Jessica L Secor, Taylor C Smits, Mark A Farber, William D Jordan, Jon S Matsumura.   

Abstract

BACKGROUND: The purpose of this study was to determine the differences in aortic morphology that would potentially affect the management of thoracic endovascular aneurysm/aortic repair between trauma and aneurysm patients.
MATERIALS AND METHODS: This was a prospective analysis of the pretreatment digital imaging of 98 traumatic injury patients and 63 aneurysm patients enrolled in multicenter regulatory studies of the Conformable GORE TAG Thoracic Device (CTAG Device) (manufactured by W.L. Gore and Associates, Flagstaff, AZ). A standardized protocol was used to perform an independent assessment of the images and measurements of the radius of curvature and proximal and distal neck diameters. The radius of curvature was measured using axial images and the proximal and distal intimal neck diameter measurements were completed using the orthogonal "centerline" view. Taper was measured over the entire treated aorta and was calculated by subtracting the distal neck diameter measurement from the proximal neck diameter. The results were analyzed with independent t-tests.
RESULTS: The trauma patients had a significantly smaller radius of curvature than aneurysm patients. There was a significant difference in the aortic neck size, with trauma patients having smaller proximal and distal intimal neck diameters. Taper was noted in trauma patients but not in aneurysm patients.
CONCLUSIONS: The aortic anatomy varies between treated aortic pathologies. Aneurysm patients have a wider arch and larger aortas when compared with trauma patients. Aneurysm patients have less taper than trauma patients. Despite these differences, both of these cohorts of patients are treatable under the broader oversizing ranges of the CTAG Device.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Aortic arch radius of curvature; Aortic disease; Neck size; Taper; Traumatic disease

Mesh:

Year:  2013        PMID: 23830365     DOI: 10.1016/j.jss.2013.05.098

Source DB:  PubMed          Journal:  J Surg Res        ISSN: 0022-4804            Impact factor:   2.192


  6 in total

1.  Aortic morphometry at endograft position as assessed by 3D image analysis affects risk of type I endoleak formation after TEVAR.

Authors:  Drosos Kotelis; Carolin Brenke; Stefan Wörz; Fabian Rengier; Karl Rohr; Hans-Ulrich Kauczor; Dittmar Böckler; Hendrik von Tengg-Kobligk
Journal:  Langenbecks Arch Surg       Date:  2015-02-22       Impact factor: 3.445

2.  Hemodynamic assessments of the ascending thoracic aortic aneurysm using fluid-structure interaction approach.

Authors:  Han Hung Yeh; Simon W Rabkin; Dana Grecov
Journal:  Med Biol Eng Comput       Date:  2017-08-11       Impact factor: 2.602

3.  Tissue engineered in-vitro vascular patch fabrication using hybrid 3D printing and electrospinning.

Authors:  Isabel Mayoral; Elisa Bevilacqua; Gorka Gómez; Abdelkrim Hmadcha; Ignacio González-Loscertales; Esther Reina; Julio Sotelo; Antonia Domínguez; Pedro Pérez-Alcántara; Younes Smani; Patricia González-Puertas; Ana Mendez; Sergio Uribe; Tarik Smani; Antonio Ordoñez; Israel Valverde
Journal:  Mater Today Bio       Date:  2022-04-14

4.  A simple patient-tailored aortic arch tangential angle measuring method to achieve better clinical results for thoracic endovascular repair of type B aortic dissection.

Authors:  Lixin Wang; Kai Hou; Xin Xu; Bin Chen; Junhao Jiang; Zhenyu Shi; Xiao Tang; Daqiao Guo; Weiguo Fu
Journal:  J Thorac Dis       Date:  2018-04       Impact factor: 2.895

5.  Traumatic aortic injury: does the anatomy of the aortic arch influence aortic trauma severity?

Authors:  Jacek Wojciechowski; Lukasz Znaniecki; Kamil Bury; Kamil Chwojnicki; Jan Rogowski
Journal:  Surg Today       Date:  2016-11-17       Impact factor: 2.549

6.  Surgical Outcomes And Postoperative Descending Aorta Morphologic Remodeling After Thoracic Endovascular Aortic Repair For Acute And Chronic Type B Aortic Dissection.

Authors:  Binshan Zha; Peng Qiu; Wentao Xie; Zhigong Zhang; Yongsheng Li; Zhiyong Chen; Huagang Zhu
Journal:  Clin Interv Aging       Date:  2019-11-06       Impact factor: 4.458

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.