Fundus fluorescein angiographic findings in patients who underwent ventricular assist device implantation.

Taylan Ozturk1, Serhad Nalcaci, Pelin Ozturk, Cagatay Engin, Tahir Yagdi, Cezmi Akkin, Mustafa Ozbaran.   

Abstract

Disruption of microcirculation in various tissues as a result of deformed blood rheology due to ventricular assist device (VAD) implantation causes novel arteriovenous malformations. Capillary disturbances and related vascular leakage in the retina and choroidea may also be seen in patients supported by VADs. We aimed to evaluate retinal vasculature deteriorations after VAD implantation. The charts of 17 patients who underwent VAD implantation surgery for the treatment of end-stage heart failure were retrospectively reviewed. Eight cases (47.1%) underwent pulsatile pump implantation (Berlin Heart EXCOR, Berlin Heart Mediprodukt GmbH, Berlin, Germany); however, nine cases (52.9%) had continuous-flow pump using centrifugal design (HeartWare, HeartWare Inc., Miramar, FL, USA). Study participants were selected among the patients who had survived with a VAD for at least 6 months, and results of detailed ophthalmologic examinations including optic coherence tomography (OCT) and fundus fluorescein angiography (FA) were documented. All of the 17 patients were male, with a mean age of 48.5 ± 14.8 years (15-67 years). Detailed ophthalmologic examinations including the evaluation of retinal vascular deteriorations via FA were performed at a mean of 11.8 ± 3.7 months of follow-up (6-18 months). Mean best-corrected visual acuity and intraocular pressure were found as logMAR 0.02 ± 0.08 and 14.6 ± 1.9 mm Hg, respectively in the study population. Dilated fundoscopy revealed severe focal arteriolar narrowing in two patients (11.8%), and arteriovenous crossing changes in four patients (23.5%); however, no pathological alteration was present in macular OCT scans. In patients with continuous-flow blood pumps, mean arm-retina circulation time (ARCT) and arteriovenous transit time (AVTT) were found to be 16.8 ± 3.0 and 12.4 ± 6.2 s, respectively; whereas those with pulsatile-flow blood pumps were found to be 17.4 ± 3.6 and 14.0 ± 2.1 s in patients (P=0.526 and P=0.356, respectively). FA also revealed a tendency for increased frequency of dye leakage from the optic disc in our study population. Except for remarkable delays in both ARCT and AVTT as well as a tendency for increased frequency of dye leakage from the optic disc, ophthalmologic evaluations revealed no other significant pathology or vascular deterioration in the retina that could be attributed to artificial heart systems.
© 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

Entities:  

Keywords:  Eye; Fluorescein angiography; Mechanical circulatory support; Ophthalmologic disorders; Retina; Ventricular assist device

Mesh:

Year:  2013        PMID: 23826834     DOI: 10.1111/aor.12123

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  1 in total

Review 1.  Physiological impact of continuous flow on end-organ function: clinical implications in the current era of left ventricular assist devices.

Authors:  Arvind Bhimaraj; Cesar Uribe; Erick E Suarez
Journal:  Methodist Debakey Cardiovasc J       Date:  2015 Jan-Mar
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.