Literature DB >> 23825013

Distinguishability and agreement with continuous data.

Josep L Carrasco1, Alejandro Caceres, Georgia Escaramis, Lluis Jover.   

Abstract

The analysis of concordance among repeated measures has received a huge amount of attention in the statistical literature leading to a range of different approaches. However, because all the approaches are able to assess the closeness among the readings taken on the same subject, the conclusions about the degree of concordance should be similar regardless the approach applied. Here, two indices to assess the concordance among continuous repeated measures, the intraclass correlation coefficient and the total deviation index, are applied and compared in two case examples. The first example concerns the repeatability of individual nutrient allocation strategy assessed by stable isotope analysis. The second example dealt with the assessment of the concordance of functional magnetic resonance imaging data that shows spatial correlation. The results differ depending upon the approach applied leading to contradictory conclusions about the degree of concordance. The reason behind these results is discussed reaching the conclusion that the total deviation index is just assessing agreement among repeated measurements, whereas the intraclass correlation coefficient assesses the concept of distinguishability among subjects that involves agreement among repeated measurements and spread of subjects at once. Therefore, the best way to select the right approach is to understand the right question behind the research hypothesis.
Copyright © 2013 John Wiley & Sons, Ltd.

Keywords:  agreement; concordance; distinguishability; functional magnetic resonance imaging; intraclass correlation coefficient; linear mixed models; repeatability; repeated measures; total deviation index

Mesh:

Substances:

Year:  2013        PMID: 23825013     DOI: 10.1002/sim.5896

Source DB:  PubMed          Journal:  Stat Med        ISSN: 0277-6715            Impact factor:   2.373


  6 in total

1.  Multiple Laser Doppler Flowmetry Probes Increase the Reproducibility of Skin Blood Flow Measurements.

Authors:  J Carter Luck; Allen R Kunselman; Michael D Herr; Cheryl A Blaha; Lawrence I Sinoway; Jian Cui
Journal:  Front Physiol       Date:  2022-05-30       Impact factor: 4.755

Review 2.  The role of fMRI in drug development.

Authors:  Owen Carmichael; Adam J Schwarz; Christopher H Chatham; David Scott; Jessica A Turner; Jaymin Upadhyay; Alexandre Coimbra; James A Goodman; Richard Baumgartner; Brett A English; John W Apolzan; Preetham Shankapal; Keely R Hawkins
Journal:  Drug Discov Today       Date:  2017-11-15       Impact factor: 7.851

3.  Statistical evaluation of test-retest studies in PET brain imaging.

Authors:  Richard Baumgartner; Aniket Joshi; Dai Feng; Francesca Zanderigo; R Todd Ogden
Journal:  EJNMMI Res       Date:  2018-02-12       Impact factor: 3.138

4.  We need to talk about reliability: making better use of test-retest studies for study design and interpretation.

Authors:  Granville J Matheson
Journal:  PeerJ       Date:  2019-05-24       Impact factor: 2.984

5.  Using multiple agreement methods for continuous repeated measures data: a tutorial for practitioners.

Authors:  Richard A Parker; Charles Scott; Vanda Inácio; Nathaniel T Stevens
Journal:  BMC Med Res Methodol       Date:  2020-06-12       Impact factor: 4.615

6.  Validating a common tick survey method: cloth-dragging and line transects.

Authors:  Pia L Kjellander; Malin Aronsson; Ulrika A Bergvall; Josep L Carrasco; Madeleine Christensson; Per-Eric Lindgren; Mikael Åkesson; Petter Kjellander
Journal:  Exp Appl Acarol       Date:  2020-11-26       Impact factor: 2.132

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.