Microleakage of the prosthetic abutment/implant interface with internal and external connection: in vitro study.

Carlos Larrucea Verdugo1, Guido Jaramillo Núñez, Ariel Acevedo Avila, Carlo Larrucea San Martín.   

Abstract

OBJECTIVE: This study determined the degree of marginal microleakage of the abutment-implant interface on platforms with Morse taper connection and external connection.
MATERIALS AND METHODS: For this in vitro study, 42 implants, 21 with external connection and 21 with Morse taper connection, were used, immersed in acrylic resin cylinders. Each implant was joined by a prosthetic abutment screw tightened at different degrees, forming the six study groups: (1) External connection, manual tightening (2) External connection, 20 Newton (N) tightening (3) External connection, 30 N tightening (4) Morse taper connection, manual tightening (5) Morse taper connection, 20 N tightening (6) orse taper connection, 30 N tightening. All samples were subjected to load cycling and thermocycling. Then, they were submerged in a solution of 0.2% methylene blue for 24 h. Finally, the microleakage was measured via 20× optical microscopy in each study group, average was obtained, and Mann-Whitney test was applied.
RESULTS: Statistically significant differences (P < 0.001) were found between the levels of microleakage presented in the Morse taper connection implants (1.48) and external connection implants (2.8) in all three types of tightening. Microleakage levels decreases when increasing torque is applied to the screws.
CONCLUSION: Morse taper connection implants showed lower levels of microleakage than external connection implants; also, it was observed that microleakage decreases in the way torque increases.
© 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  external connection; implants; internal connection; microfiltration; torque

Mesh:

Substances:

Year:  2013        PMID: 23822097     DOI: 10.1111/clr.12217

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  11 in total

Review 1.  Microleakage at the Different Implant Abutment Interface: A Systematic Review.

Authors:  Sunil Kumar Mishra; Ramesh Chowdhary; Shail Kumari
Journal:  J Clin Diagn Res       Date:  2017-06-01

Review 2.  Morse taper dental implants and platform switching: The new paradigm in oral implantology.

Authors:  José Paulo Macedo; Jorge Pereira; Brendan R Vahey; Bruno Henriques; Cesar A M Benfatti; Ricardo S Magini; José López-López; Júlio C M Souza
Journal:  Eur J Dent       Date:  2016 Jan-Mar

3.  Sphere-plane methodology to evaluate the wear of titanium of dental implants: a research proposal.

Authors:  Teresa Almeida Mendes; João Caramês; Luís Pires Lopes; Amílcar Lopes Ramalho
Journal:  BMC Res Notes       Date:  2018-07-31

4.  Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit.

Authors:  Jorge Vélez; Jesús Peláez; Carlos López-Suárez; Rubén Agustín-Panadero; Celia Tobar; María J Suárez
Journal:  J Clin Med       Date:  2020-07-24       Impact factor: 4.241

5.  Bacterial Microleakage at the Implant-Abutment Interface: An In Vitro Study.

Authors:  Simonetta D'Ercole; Tatiane Cristina Dotta; Marzieh Ramezani Farani; Niloofar Etemadi; Giovanna Iezzi; Luca Comuzzi; Adriano Piattelli; Morena Petrini
Journal:  Bioengineering (Basel)       Date:  2022-06-26

6.  In Vitro Bacterial Leakage at the Implant-Abutment Connection of Two Dental Implant Systems with Internal Connection.

Authors:  Azadeh Khajavi; Shabnam Mohseni; Amir Peymani; Mehrak Amjadi
Journal:  Front Dent       Date:  2020-12-08

7.  Microleakage assessment of CAD-CAM Cobalt-Chrome and Zirconia abutments on a conical connection dental implant: A comparative in vitro study.

Authors:  Pedro Molinero-Mourelle; Andrea Roccuzzo; Burak Yilmaz; Walter Yu Hang Lam; Edmond H N Pow; Jaime Del Río Highsmith; Miguel Gómez-Polo
Journal:  Clin Oral Implants Res       Date:  2022-07-21       Impact factor: 5.021

8.  Impact of crestal and subcrestal implant placement in peri-implant bone: A prospective comparative study.

Authors:  Hilario Pellicer-Chover; María Peñarrocha-Diago; David Peñarrocha-Oltra; Sonia Gomar-Vercher; Rubén Agustín-Panadero; Miguel Peñarrocha-Diago
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2016-01-01

9.  Complications of Fixed Full-Arch Implant-Supported Metal-Ceramic Prostheses.

Authors:  Ignacio Gonzalez-Gonzalez; Hector deLlanos-Lanchares; Aritza Brizuela-Velasco; Jose-Antonio Alvarez-Riesgo; Santiago Llorente-Pendas; Mariano Herrero-Climent; Angel Alvarez-Arenal
Journal:  Int J Environ Res Public Health       Date:  2020-06-14       Impact factor: 3.390

10.  Comparative study of bacterial microfiltration in the implant-abutment interface, with straight and conical internal connections, in vitro.

Authors:  Larrucea V Carlos; Navarro C Carlos; Larrucea Sm Karina; Boda K Sunil; Padilla E Carlos; Lobos G Olga
Journal:  Clin Exp Dent Res       Date:  2021-06-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.