Literature DB >> 23820285

Visualization of thrombotic deposits in extracorporeal membrane oxygenation devices using multidetector computed tomography: a feasibility study.

Christian Dornia1, Alois Philipp, Stefan Bauer, Patrick Hoffstetter, Karla Lehle, Christof Schmid, Matthias Lubnow, Christian Stroszczynski, Andreas G Schreyer.   

Abstract

Despite heparin coating and systemic anticoagulation, thrombotic clot formation is a serious complication in extracorporeal membrane oxygenation (ECMO). We describe our first results of visualization of thrombotic deposits in ECMO devices using advanced multidetector computed tomography (MDCT). A bioline-coated polymethylpentene membrane oxygenator (MO) after 8 days of ECMO treatment (device 1) and a factory-sealed MO serving as an internal quality control (device 2) were analyzed with three-dimensional (3D) visualization volume rendering technique (VRT) using a 0.6 mm3 voxel isotropic MDCT dataset. After the computed tomography (CT) scan, device 1 was anatomically dissected for direct visualization of potential deposits and further analyzed by scanning electron microscopy (SEM). The VRT 3D model based on the MDCT dataset of device 1 showed red-coded areas within the gas exchange surface of the device consistent with fibrous and cellular deposits. These deposits could be confirmed by anatomical dissection of the device and by SEM. Device 2 showed no signs of clot formation in MDCT using the same VRT settings. It was demonstrated that MDCT with VRT is able to detect thrombotic deposits in ECMO devices under ex vivo conditions. MDCT allows direct visualization of the actual thrombus load of a used ECMO device as well as the quantification of the thrombus volume and could, therefore, play a significant role in better understanding the oxygenator thrombosis in modern ECMO treatment.

Entities:  

Mesh:

Year:  2013        PMID: 23820285     DOI: 10.1097/MAT.0b013e3182976eff

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  9 in total

1.  Extracorporeal oxygenation and COVID-19 epidemic: is the membrane fail-safe to cross contamination?

Authors:  Enrico Squiccimarro; Ruggiero Rociola; Renard Gerhardus Haumann; Salvatore Grasso; Roberto Lorusso; Domenico Paparella
Journal:  ASAIO J       Date:  2020-05-07       Impact factor: 2.872

2.  Effects on membrane lung gas exchange of an intermittent high gas flow recruitment maneuver: preliminary data in veno-venous ECMO patients.

Authors:  Luigi Castagna; Alberto Zanella; Vittorio Scaravilli; Federico Magni; Salua Abd El Aziz El Sayed Deab; Michele Introna; Francesco Mojoli; Giacomo Grasselli; Antonio Pesenti; Nicolò Patroniti
Journal:  J Artif Organs       Date:  2015-03-26       Impact factor: 1.731

Review 3.  Development and hemocompatibility testing of nitric oxide releasing polymers using a rabbit model of thrombogenicity.

Authors:  Terry C Major; Hitesh Handa; Gail M Annich; Robert H Bartlett
Journal:  J Biomater Appl       Date:  2014-06-16       Impact factor: 2.646

4.  Effect of blood flow on platelets, leukocytes, and extracellular vesicles in thrombosis of simulated neonatal extracorporeal circulation.

Authors:  Andrew D Meyer; Anjana R Rishmawi; Robin Kamucheka; Crystal Lafleur; Andriy I Batchinsky; Nigel Mackman; Andrew P Cap
Journal:  J Thromb Haemost       Date:  2019-11-14       Impact factor: 5.824

5.  The Effects of the Combined Argatroban/Nitric Oxide-Releasing Polymer on Platelet Microparticle-Induced Thrombogenicity in Coated Extracorporeal Circuits.

Authors:  Tiffany R Bellomo; Mark A Jeakle; Mark E Meyerhoff; Robert H Bartlett; Terry C Major
Journal:  ASAIO J       Date:  2021-05-01       Impact factor: 3.826

6.  Technical complications during veno-venous extracorporeal membrane oxygenation and their relevance predicting a system-exchange--retrospective analysis of 265 cases.

Authors:  Matthias Lubnow; Alois Philipp; Maik Foltan; Tone Bull Enger; Dirk Lunz; Thomas Bein; Assad Haneya; Christof Schmid; Günter Riegger; Thomas Müller; Karla Lehle
Journal:  PLoS One       Date:  2014-12-02       Impact factor: 3.240

7.  Life span of different extracorporeal membrane systems for severe respiratory failure in the clinical practice.

Authors:  Alois Philipp; Filip De Somer; Maik Foltan; Andre Bredthauer; Lars Krenkel; Florian Zeman; Karla Lehle
Journal:  PLoS One       Date:  2018-06-01       Impact factor: 3.240

8.  Extracorporeal Oxygenation and Coronavirus Disease 2019 Epidemic: Is the Membrane Fail-Safe to Cross Contamination?

Authors:  Enrico Squiccimarro; Ruggiero Rociola; Renard Gerhardus Haumann; Salvatore Grasso; Roberto Lorusso; Domenico Paparella
Journal:  ASAIO J       Date:  2020-08       Impact factor: 2.872

Review 9.  Toward a Long-Term Artificial Lung.

Authors:  Jutta Arens; Oliver Grottke; Axel Haverich; Lars S Maier; Thomas Schmitz-Rode; Ulrich Steinseifer; H P Wendel; Rolf Rossaint
Journal:  ASAIO J       Date:  2020-08       Impact factor: 3.826

  9 in total