Replacing manual sphygmomanometers with automated blood pressure measurement in routine clinical practice.

Martin G Myers1.   

Abstract

1. Conventional manual measurement of blood pressure (BP) in clinical practice is no longer considered to be the best method for evaluating a patient's BP status. Home BP and 24 h ambulatory BP monitoring are now recommended for the diagnosis and management of hypertension.  2. Recent studies provide an alternative to conventional office BP, namely automated office (AO) BP, which involves multiple BP readings taken with a fully automated device with the patient resting quietly alone. Automated office BP is preferable to routine manual office BP in that it exhibits improved accuracy and a stronger relationship to both ambulatory BP and target organ damage. 3. Having the patient alone eliminates conversation between the patient and the observer, a cause of 'white coat hypertension'. The use of an automated device improves accuracy, reduces digit preference, minimizes observer bias and facilitates the recording of multiple BP readings.  4. Comparative BP data obtained in clinical studies in both research settings and routine community practice support the use of a cut-off point of 135/85 mmHg for defining hypertension using AOBP, which is the same cut-off point currently recommended for awake ambulatory BP and home BP. 5. Reduction of the white coat response using AOBP should reduce the need to monitor patients with ambulatory BP and home BP after initiation of antihypertensive therapy. There is now sufficient evidence to consider replacing manual office BP with AOBP in routine clinical practice.
© 2013 Wiley Publishing Asia Pty Ltd.

Entities:  

Keywords:  automated blood pressure measurement; hypertension diagnosis; white coat hypertension

Mesh:

Year:  2014        PMID: 23819734     DOI: 10.1111/1440-1681.12149

Source DB:  PubMed          Journal:  Clin Exp Pharmacol Physiol        ISSN: 0305-1870            Impact factor:   2.557


  10 in total

1.  Comparison of minute distribution frequency for anesthesia start and end times from an anesthesia information management system and paper records.

Authors:  Michael Phelps; Asad Latif; Robert Thomsen; Martin Slodzinski; Rahul Raghavan; Sharon Leigh Paul; Jerry Stonemetz
Journal:  J Clin Monit Comput       Date:  2016-06-07       Impact factor: 2.502

Review 2.  Hypertension in Developing Countries: A Major Challenge for the Future.

Authors:  M Mohsen Ibrahim
Journal:  Curr Hypertens Rep       Date:  2018-05-01       Impact factor: 5.369

Review 3.  Choosing the optimal method of blood pressure measurement for limited-resource rural communities in the "Community Health Assessment Program-Philippines".

Authors:  Dale Guenter; Ricardo Angeles; Janusz Kaczorowski; Gina Agarwal; Fortunato L Cristobal; Rosemarie Arciaga; John F Smith; Pattapong Kessomboon; Faical Jarraya; Rodelin Agbulos; Floro Dave Arnuco; Jerome Barrera; Susan Dimitry; Elgie Gregorio; Servando Halili; Norvie T Jalani; Nusaraporn Kessomboon; Maita Ladeza; Lisa Dolovich
Journal:  J Clin Hypertens (Greenwich)       Date:  2017-05-30       Impact factor: 3.738

4.  Blood Pressure Measurement Modalities: A Primer for Busy Practitioners.

Authors:  L Allen Kindman; J Rick Turner; John Lee
Journal:  J Clin Hypertens (Greenwich)       Date:  2015-11-12       Impact factor: 3.738

Review 5.  South African hypertension practice guideline 2014.

Authors:  Y K Seedat; B L Rayner; Y Veriava
Journal:  Cardiovasc J Afr       Date:  2014 Nov-Dec       Impact factor: 1.167

Review 6.  Clinical value of ambulatory blood pressure in pediatric patients after renal transplantation.

Authors:  Rafael T Krmar; Jorge R Ferraris
Journal:  Pediatr Nephrol       Date:  2017-08-25       Impact factor: 3.714

7.  Association of Deepwater Horizon Oil Spill Response and Cleanup Work With Risk of Developing Hypertension.

Authors:  Richard K Kwok; W Braxton Jackson; Matthew D Curry; Patricia A Stewart; John A McGrath; Mark Stenzel; Tran B Huynh; Caroline P Groth; Gurumurthy Ramachandran; Sudipto Banerjee; Gregory C Pratt; Aubrey K Miller; Xian Zhang; Lawrence S Engel; Dale P Sandler
Journal:  JAMA Netw Open       Date:  2022-02-01

8.  Manual or automated sphygmomanometer? A historical cohort to quantify measurement bias in blood pressure recording.

Authors:  Arash A Nargesi; Zaniar Ghazizadeh; Mehrdad Larry; Afsaneh Morteza; Firuzeh Heidari; Firuzeh Asgarani; Alireza Esteghamati; Kazem Mohammad; Manouchehr Nakhjavani
Journal:  J Clin Hypertens (Greenwich)       Date:  2014-09-08       Impact factor: 3.738

9.  A new automatic blood pressure kit auscultates for accurate reading with a smartphone: A diagnostic accuracy study.

Authors:  Hongjun Wu; Bingjian Wang; Xinpu Zhu; Guang Chu; Zhi Zhang
Journal:  Medicine (Baltimore)       Date:  2016-08       Impact factor: 1.889

10.  Measurement of Blood Pressure by Ultrasound-The Applicability of Devices, Algorithms and a View in Local Hemodynamics.

Authors:  Moritz Meusel; Philipp Wegerich; Berit Bode; Elena Stawschenko; Kristina Kusche-Vihrog; Horst Hellbrück; Hartmut Gehring
Journal:  Diagnostics (Basel)       Date:  2021-12-02
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.