Literature DB >> 23817542

A clinical protocol for intraoral digital impression of screw-retained CAD/CAM framework on multiple implants based on wavefront sampling technology.

Angel Moreno1, Beatriz Giménez, Mutlu Özcan, Guillermo Pradíes.   

Abstract

PURPOSE: To obtain an accurate CAD/CAM metal framework over 6 implants using a Chairside Intraoral Scanner based on the principle of active (optical) wavefront sampling.
MATERIAL AND METHODS: Six prototype cylindrical scan bodies screwed in the implants were used to obtain an intraoral digital impression. A conventional resin tooth try-in was fabricated and digitized with an extraoral scanner, and this dataset was merged to the digital data obtained from the intraoral impression to calculate the best framework design with advanced CAD software. The framework was fabricated with a 5-axis computer numerical control milling unit. Three clinical tests (saliva intrusion, Sheffield test, and screw resistance test) were performed to assess the fit of the framework.
RESULTS: Under 3 clinical tests, an accurate fit was observed.
CONCLUSION: The case presented in this report proposes a new clinical protocol for obtaining accurate digital impressions of multiple implants.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23817542     DOI: 10.1097/ID.0b013e3182980fe9

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  4 in total

Review 1.  Precision and practical usefulness of intraoral scanners in implant dentistry: A systematic literature review.

Authors:  Ignacio García-Gil; Jorge Cortés-Bretón-Brinkmann; Jaime Jiménez-García; Jesus Peláez-Rico; María-Jesús Suárez-García
Journal:  J Clin Exp Dent       Date:  2020-08-01

2.  Effect of full arch two scanning techniques on the accuracy of overdenture conventional and CAD/CAM Co-Cr bars.

Authors:  Ali Alenezi; Mohammed Yehya; Mohamed Alkhodary
Journal:  Saudi Dent J       Date:  2022-08-28

3.  Accuracy of Intraoral Digital Impressions for Whole Upper Jaws, Including Full Dentitions and Palatal Soft Tissues.

Authors:  Ning Gan; Yaoyang Xiong; Ting Jiao
Journal:  PLoS One       Date:  2016-07-06       Impact factor: 3.240

4.  Intraoral Digital Impressions for Virtual Occlusal Records: Section Quantity and Dimensions.

Authors:  Eneko Solaberrieta; Asier Garmendia; Aritza Brizuela; Jose Ramon Otegi; Guillermo Pradies; Andras Szentpétery
Journal:  Biomed Res Int       Date:  2016-01-10       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.