Literature DB >> 23813113

Comparison of far and near contrast sensitivity in patients symmetrically implanted with multifocal and monofocal IOLs.

Miguel A Gil1, Consuelo Varón, Genís Cardona, Fidel Vega, José A Buil.   

Abstract

PURPOSE: A prospective, randomized, double-masked, clinical trial was designed to evaluate distance and near contrast sensitivity (CS) in patients symmetrically, and randomly, implanted with 4 different multifocal intraocular lens (MIOL) designs (ReSTOR SN6AD1, ReSTOR SN60D3, ReZoom NXG, and Tecnis ZMA00) and a monofocal control group (Tecnis ZA9003), 6 months after cataract intervention.
METHODS: Photopic, mesopic, and mesopic with glare distance CS, as well as photopic near CS, was evaluated with the CSV-1000 CS test and the Vistech VCTS 6000 system, respectively, in a group of 180 patients attending the ophthalmology department of Sant Pau Hospital, Barcelona, for cataract intervention and lens implantation.
RESULTS: Statistically and clinically significant differences were found between the monofocal and multifocal lens groups at all spatial frequencies and illumination conditions, both during distance and near CS evaluation (all p<0.05), with the monofocal lens offering the best performance in all cases. Contrast sensitivity was similarly compromised in all MIOL models at distance, although MIOLs with diffractive optics and aspheric profiles showed a non-statistically significant trend to perform better in mesopic conditions. Near CS was lower for refractive, distance dominant lens designs, particularly at medium to high spatial frequencies.
CONCLUSIONS: The present results, which reflect intraocular lens (IOL) characteristics in optics, profile, and add power, may contribute to help surgeons decide on the type of IOL most suitable for each patient by taking into consideration the individual needs for critical distance and near vision, both in terms of visual acuity and contrast sensitivity.

Entities:  

Mesh:

Year:  2013        PMID: 23813113     DOI: 10.5301/ejo.5000335

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  11 in total

1.  Optical Coherence Tomography: Critical Tool to Manage Expectations after Cataract Extraction.

Authors:  Raquel Goldhardt; Bradley Simon Rosen
Journal:  Curr Ophthalmol Rep       Date:  2020-06-06

2.  Postoperative visual performance with a bifocal and trifocal diffractive intraocular lens during a 1-year follow-up.

Authors:  Peter Mojzis; Lucia Kukuckova; Katarina Majerova; Peter Ziak; David P Piñero
Journal:  Int J Ophthalmol       Date:  2017-10-18       Impact factor: 1.779

3.  Comparison of visual outcomes after bilateral implantation of two intraocular lenses with distinct diffractive optics.

Authors:  André Lins de Medeiros; Flavio Jones Saraiva; Camila Ishii Iguma; Danilo Varela Kniggendorf; Guilherme Alves; Mario Augusto Pereira Dias Chaves; Cesar Vilar; Antonio Francisco Pimenta Motta; Pedro Carlos Carricondo; Celso Takashi Nakano; Walton Nosé; Wilson Takashi Hida
Journal:  Clin Ophthalmol       Date:  2019-08-29

4.  Extended depth of focus lens implantation after radial keratotomy.

Authors:  Brandon J Baartman; Kayla Karpuk; Bradley Eichhorn; Tanner J Ferguson; Ramu G Sudhagoni; John P Berdahl; Vance M Thompson
Journal:  Clin Ophthalmol       Date:  2019-07-30

5.  Comparison of three different diffractıve multifocal intraocular lenses with a +2.5, +3.0, and +3.75 diopter additıon power.

Authors:  Emre Altinkurt; Orkun Muftuoglu
Journal:  Saudi J Ophthalmol       Date:  2019-11-06

6.  Cases of replacing diffractive bifocal intraocular lens with extended depth of focus intraocular lens due to waxy vision.

Authors:  Ryu Takabatake; Makiko Takahashi; Takuya Yoshimoto; Fumiaki Higashijima; Yuka Kobayashi; Chiemi Yamashiro; Kazuhiro Kimura
Journal:  PLoS One       Date:  2021-10-29       Impact factor: 3.240

Review 7.  Current management of presbyopia.

Authors:  Pandelis A Papadopoulos; Alexandros P Papadopoulos
Journal:  Middle East Afr J Ophthalmol       Date:  2014 Jan-Mar

8.  Influence of extended depth of focus intraocular lenses on visual field sensitivity.

Authors:  Makiko Takahashi; Chiemi Yamashiro; Takuya Yoshimoto; Yuka Kobayashi; Fumiaki Higashijima; Masaaki Kobayashi; Makoto Hatano; Manami Ohta; Tomohiko Nagai; Shinichiro Teranishi; Katsuyoshi Suzuki; Ryu Takabatake; Kazuhiro Kimura
Journal:  PLoS One       Date:  2020-09-14       Impact factor: 3.240

Review 9.  Multifocal intraocular lenses and retinal diseases.

Authors:  Andrzej Grzybowski; Piotr Kanclerz; Raimo Tuuminen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-01-18       Impact factor: 3.117

10.  Clinical Results of Diffractive, Refractive, Hybrid Multifocal, and Monofocal Intraocular Lenses.

Authors:  Agnieszka Dyrda; Ana Martínez-Palmer; Daniel Martín-Moral; Amanda Rey; Antonio Morilla; Miguel Castilla-Martí; Janny Aronés-Santivañez
Journal:  J Ophthalmol       Date:  2018-06-25       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.