Literature DB >> 23810452

Comparison of circumferential pelvic sheeting versus the T-POD on unstable pelvic injuries: A cadaveric study of stability.

Mark L Prasarn1, Bryan Conrad, John Small, MaryBeth Horodyski, Glenn R Rechtine.   

Abstract

OBJECTIVES: Commercially available binder devices are commonly used in the acute treatment of pelvic fractures, while many advocate simply placing a circumferential sheet for initial stabilization of such injuries. We sought to determine whether or not the T-POD would provide more stability to an unstable pelvic injury as compared to circumferential pelvic sheeting.
METHODS: Unstable pelvic injuries (OTA type 61-C-1) were surgically created in five fresh, lightly embalmed whole human cadavers. Electromagnetic sensors were placed on each hemi-pelvis. The amount of angular motion during testing was measured using a Fastrak, three-dimensional, electromagnetic motion analysis device (Polhemus Inc., Colchester, VT). Either a T-POD or circumferential sheet was applied in random order for testing. The measurements recorded in this investigation included maximum displacements for sagittal, coronal, and axial rotation during application of the device, bed transfer, log-rolling, and head of bed elevation.
RESULTS: There were no differences in motion of the injured hemi-pelvis during application of either the T-POD or circumferential sheet. During the bed transfer, log-rolling, and head of bed elevation, there were no significant differences in displacements observed when the pelvis was immobilized with either a sheet or pelvic binder (T-POD).
CONCLUSIONS: A circumferential pelvic sheet is more readily available, costs less, is more versatile, and is equally as efficacious at immobilizing the unstable pelvis as compared to the T-POD. We advocate the use of circumferential sheeting for temporary stabilization of unstable pelvic injuries.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Binder; Fracture; Immobilization; Pelvic; Sheeting; Stability

Mesh:

Year:  2013        PMID: 23810452     DOI: 10.1016/j.injury.2013.05.016

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  6 in total

1.  [Positioning of external pelvic stabilization devices in patients with multiple injuries : Retrospective computed tomographic evaluation].

Authors:  G Jansen; T Hefke; G Wittenberg; T Vordemvenne; F Mertzlufft
Journal:  Anaesthesist       Date:  2018-10-08       Impact factor: 1.041

2.  Resuscitation of Polytrauma Patients: The Management of Massive Skeletal Bleeding.

Authors:  Enrique Guerado; Maria Luisa Bertrand; Luis Valdes; Encarnacion Cruz; Juan Ramon Cano
Journal:  Open Orthop J       Date:  2015-07-31

Review 3.  Effectiveness of non invasive external pelvic compression: a systematic review of the literature.

Authors:  Peyman Bakhshayesh; Tarek Boutefnouchet; Anna Tötterman
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2016-05-18       Impact factor: 2.953

4.  The T-pod is as stable as supraacetabular fixation using 1 or 2 Schanz screws in partially unstable pelvic fractures: a biomechanical study.

Authors:  Christian Zeckey; Adrian Cavalcanti Kußmaul; Eduardo M Suero; Christian Kammerlander; Axel Greiner; Matthias Woiczinski; Christian Braun; Wilhelm Flatz; Wolfgang Boecker; Christopher A Becker
Journal:  Eur J Med Res       Date:  2020-07-18       Impact factor: 2.175

Review 5.  Prehospital control of life-threatening truncal and junctional haemorrhage is the ultimate challenge in optimizing trauma care; a review of treatment options and their applicability in the civilian trauma setting.

Authors:  S E van Oostendorp; E C T H Tan; L M G Geeraedts
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2016-09-13       Impact factor: 2.953

6.  Damage control orthopaedics: State of the art.

Authors:  Enrique Guerado; Maria Luisa Bertrand; Juan Ramon Cano; Ana María Cerván; Adolfo Galán
Journal:  World J Orthop       Date:  2019-01-18
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.