Literature DB >> 23810188

Comparison between the deconvolution and maximum slope 64-MDCT perfusion analysis of the esophageal cancer: is conversion possible?

A Djuric-Stefanovic1, Dj Saranovic, D Masulovic, A Ivanovic, P Pesko.   

Abstract

PURPOSE: To estimate if CT perfusion parameter values of the esophageal cancer, which were obtained with the deconvolution-based software and maximum slope algorithm are in agreement, or at least interchangeable.
METHODS: 278 esophageal tumor ROIs, derived from 35 CT perfusion studies that were performed with a 64-MDCT, were analyzed. "Slice-by-slice" and average "whole-covered-tumor-volume" analysis was performed. Tumor blood flow and blood volume were manually calculated from the arterial tumor-time-density graphs, according to the maximum slope methodology (BF(ms) and BV(ms)), and compared with the corresponding perfusion values, which were automatically computed by commercial deconvolution-based software (BF(deconvolution) and BV(deconvolution)), for the same tumor ROIs. Statistical analysis was performed using Wilcoxon matched-pairs test, paired-samples t-test, Spearman and Pearson correlation coefficients, and Bland-Altman agreement plots.
RESULTS: BF(deconvolution) (median: 74.75 ml/min/100g, range, 18.00-230.5) significantly exceeded the BF(ms) (25.39 ml/min/100g, range, 7.13-96.41) (Z=-14.390, p<0.001), while BV(deconvolution) (median: 5.70 ml/100g, range: 2.10-15.90) descended the BV(ms) (9.37 ml/100g, range: 3.44-19.40) (Z=-13.868, p<0.001). Both pairs of perfusion measurements significantly correlated with each other: BF(deconvolution), versus BF(ms) (rS=0.585, p<0.001), and BV(deconvolution), versus BV(ms) (rS=0.602, p<0.001). Geometric mean BF(deconvolution)/BF(ms) ratio was 2.8 (range, 1.1-6.8), while geometric mean BV(deconvolution)/BV(ms) ratio was 0.6 (range, 0.3-1.1), within 95% limits of agreement.
CONCLUSIONS: Significantly different CT perfusion values of the esophageal cancer blood flow and blood volume were obtained by deconvolution-based and maximum slope-based algorithms, although they correlated significantly with each other. Two perfusion-measuring algorithms are not interchangeable because too wide ranges of the conversion factors were found.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  CT perfusion; Deconvolution; Esophageal cancer; Maximum slope; Multi-detector computed tomography

Mesh:

Year:  2013        PMID: 23810188     DOI: 10.1016/j.ejrad.2013.05.038

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  7 in total

1.  Use of patient outcome endpoints to identify the best functional CT imaging parameters in metastatic renal cell carcinoma patients.

Authors:  Jill Rachel Mains; Frede Donskov; Erik Morre Pedersen; Hans Henrik Torp Madsen; Jesper Thygesen; Kennet Thorup; Finn Rasmussen
Journal:  Br J Radiol       Date:  2018-01-02       Impact factor: 3.039

2.  Can dual-energy CT replace perfusion CT for the functional evaluation of advanced hepatocellular carcinoma?

Authors:  Sébastien Mulé; Frédéric Pigneur; Ronan Quelever; Arthur Tenenhaus; Laurence Baranes; Philippe Richard; Vania Tacher; Edouard Herin; Hugo Pasquier; Maxime Ronot; Alain Rahmouni; Valérie Vilgrain; Alain Luciani
Journal:  Eur Radiol       Date:  2017-11-22       Impact factor: 5.315

3.  Dynamic perfusion CT - A promising tool to diagnose pancreatic ductal adenocarcinoma.

Authors:  Inga Zaborienė; Giedrius Barauskas; Antanas Gulbinas; Povilas Ignatavičius; Saulius Lukoševičius; Kristina Žvinienė
Journal:  Open Med (Wars)       Date:  2021-02-05

4.  CT-perfusion measurements in pancreatic carcinoma with different kinetic models: Is there a chance for tumour grading based on functional parameters?

Authors:  Sven Schneeweiß; Marius Horger; Anja Grözinger; Konstantin Nikolaou; Dominik Ketelsen; Roland Syha; Gerd Grözinger
Journal:  Cancer Imaging       Date:  2016-12-15       Impact factor: 3.909

5.  The Comparison of Computed Tomography Perfusion, Contrast-Enhanced Computed Tomography and Positron-Emission Tomography/Computed Tomography for the Detection of Primary Esophageal Carcinoma.

Authors:  Berhan Genc; Mecit Kantarci; Recep Sade; Ebru Orsal; Hayri Ogul; Aylin Okur; Yener Aydin; Leyla Karaca; Atilla Eroğlu
Journal:  Med Princ Pract       Date:  2016-01-19       Impact factor: 1.927

6.  320-row CT renal perfusion imaging in patients with aortic dissection: A preliminary study.

Authors:  Dongting Liu; Jiayi Liu; Zhaoying Wen; Yu Li; Zhonghua Sun; Qin Xu; Zhanming Fan
Journal:  PLoS One       Date:  2017-02-09       Impact factor: 3.240

7.  Comparative analysis of two mathematical algorithms for the calculation of computed tomography perfusion parameters in the healthy and diseased pancreas.

Authors:  Kehua Pan; Hongqing Wang; Xiaoyu Chen; Xiaocui Ye; Zhao Zhang; Xiao Chen; Xiufen Jia
Journal:  J Appl Clin Med Phys       Date:  2021-12-13       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.