Literature DB >> 23809902

Realization of a multipath ultrasonic gas flowmeter based on transit-time technique.

Qiang Chen1, Weihua Li, Jiangtao Wu.   

Abstract

A microcomputer-based ultrasonic gas flowmeter with transit-time method is presented. Modules of the flowmeter are designed systematically, including the acoustic path arrangement, ultrasound emission and reception module, transit-time measurement module, the software and so on. Four 200 kHz transducers forming two acoustic paths are used to send and receive ultrasound simultaneously. The synchronization of the transducers can eliminate the influence caused by the inherent switch time in simple chord flowmeter. The distribution of the acoustic paths on the mechanical apparatus follows the Tailored integration, which could reduce the inherent error by 2-3% compared with the Gaussian integration commonly used in the ultrasonic flowmeter now. This work also develops timing modules to determine the flight time of the acoustic signal. The timing mechanism is different from the traditional method. The timing circuit here adopts high capability chip TDC-GP2, with the typical resolution of 50 ps. The software of Labview is used to receive data from the circuit and calculate the gas flow value. Finally, the two paths flowmeter has been calibrated and validated on the test facilities for air flow in Shaanxi Institute of Measurement & Testing.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Flowmeter; Transit time; Ultrasonic

Mesh:

Year:  2013        PMID: 23809902     DOI: 10.1016/j.ultras.2013.06.001

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  3 in total

1.  Development of an ultrasonic airflow measurement device for ducted air.

Authors:  Andrew B Raine; Nauman Aslam; Christopher P Underwood; Sean Danaher
Journal:  Sensors (Basel)       Date:  2015-05-06       Impact factor: 3.576

2.  Flow Velocity Measurement Using a Spatial Averaging Method with Two-Dimensional Flexural Ultrasonic Array Technology.

Authors:  Lei Kang; Andrew Feeney; Riliang Su; David Lines; Sivaram Nishal Ramadas; George Rowlands; Steve Dixon
Journal:  Sensors (Basel)       Date:  2019-11-04       Impact factor: 3.576

3.  Design and Implementation of an Ultrasonic Flowmeter Based on the Cross-Correlation Method.

Authors:  Rui Ren; Hongliang Wang; Xiaolei Sun; He Quan
Journal:  Sensors (Basel)       Date:  2022-10-02       Impact factor: 3.847

  3 in total