Literature DB >> 23809692

A detailed evaluation of TomoDirect 3DCRT planning for whole-breast radiation therapy.

Emma C Fields1, Rachel Rabinovitch, Nicole E Ryan, Moyed Miften, David C Westerly.   

Abstract

The goal of this work was to develop planning strategies for whole-breast radiotherapy (WBRT) using TomoDirect three-dimensional conformal radiation therapy (TD-3DCRT) and to compare TD-3DCRT with conventional 3DCRT and TD intensity-modulated radiation therapy (TD-IMRT) to evaluate differences in WBRT plan quality. Computed tomography (CT) images of 10 women were used to generate 150 WBRT plans, varying in target structures, field width (FW), pitch, and number of beams. Effects on target and external maximum doses (EMD), organ-at-risk (OAR) doses, and treatment time were assessed for each parameter to establish an optimal planning technique. Using this technique, TD-3DCRT plans were generated and compared with TD-IMRT and standard 3DCRT plans. FW 5.0cm with pitch = 0.250cm significantly decreased EMD without increasing lung V20Gy. Increasing number of beams from 2 to 6 and using an additional breast planning structure decreased EMD though increased lung V20Gy. Changes in pitch had minimal effect on plan metrics. TD-3DCRT plans were subsequently generated using FW 5.0cm, pitch = 0.250cm, and 2 beams, with additional beams or planning structures added to decrease EMD when necessary. TD-3DCRT and TD-IMRT significantly decreased target maximum dose compared to standard 3DCRT. FW 5.0cm with 2 to 6 beams or novel planning structures or both allow for TD-3DCRT WBRT plans with excellent target coverage and OAR doses. TD-3DCRT plans are comparable to plans generated using TD-IMRT and provide an alternative to conventional 3DCRT for WBRT.
© 2013 American Association of Medical Dosimetrists.

Entities:  

Keywords:  3DCRT; TomoDirect; Whole-breast radiation therapy

Mesh:

Year:  2013        PMID: 23809692     DOI: 10.1016/j.meddos.2013.04.008

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  4 in total

1.  Use of tomotherapy in treatment of synchronous bilateral breast cancer: dosimetric comparison study.

Authors:  T Wadasadawala; B Visariya; R Sarin; R R Upreti; S Paul; R Phurailatpam
Journal:  Br J Radiol       Date:  2015-01-21       Impact factor: 3.039

2.  Efficacy and Safety of PD-1/PD-L1 Inhibitor Chemotherapy Combined with Lung Cancer Fang No. 1 in Relapsed and Refractory SCLC: A Retrospective Observational Study.

Authors:  Lihua Wang; Xiaoxia Lei; Xin Wang
Journal:  Comput Math Methods Med       Date:  2022-05-09       Impact factor: 2.809

3.  Static beam tomotherapy as an optimisation method in whole-breast radiation therapy (WBRT).

Authors:  Matthew Squires; Yunfei Hu; Mikel Byrne; Ben Archibald-Heeren; Sonja Cheers; Bruno Bosco; Amy Teh; Andrew Fong
Journal:  J Med Radiat Sci       Date:  2017-06-04

4.  Dosimetric and Radiobiological Comparison of Five Techniques for Postmastectomy Radiotherapy with Simultaneous Integrated Boost.

Authors:  Du Tang; Zhan Liang; Fada Guan; Zhen Yang
Journal:  Biomed Res Int       Date:  2020-07-21       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.