Fatigue resistance and retentive force of cast clasps treated by shot peening.

Ai Tokue1, Tohru Hayakawa, Chikahiro Ohkubo.   

Abstract

PURPOSE: The fatigue failure of denture clasps has often been observed in removable partial denture rehabilitation. To increase their fatigue strength, shot peening was evaluated as a surface treatment. In this study, we evaluated the fatigue resistance and retention of cast clasps by using a shot peening treatment.
METHODS: A cobalt-chromium (Co-Cr) alloy, commercial pure titanium (CP Ti), silver-palladium-gold (Ag-Pd-Au), and a gold-platinum (Au-Pt) alloy were cast and then treated with shot peening. The retentive forces of the clasps were measured up to a repetition of 10,000insertion/removal cycles in distilled water at 37°C. A fatigue test was also performed using a 15-mm cantilever. Specimens were loaded with a constant deflection of 2.0mm with 20Hz. A shot peening treatment indicated a better stability of retentive forces than that without shot peening. The retentive force of Co-Cr clasps without shot peening was remarkably decreased at 500 cycles of insertion/removal repetition.
RESULTS: The clasps with a shot peening treatment provided approximately 1.4-3.6 times higher fatigue strengths than those without a shot peening treatment.
CONCLUSION: To prevent the fatigue failure of the denture clasps and use the dentures for long term, a shot peening treatment would be recommended.
Copyright © 2013 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Clasp; Fatigue strength; Shot peening; Surface modification; Titanium

Mesh:

Substances:

Year:  2013        PMID: 23809297     DOI: 10.1016/j.jpor.2013.01.006

Source DB:  PubMed          Journal:  J Prosthodont Res        ISSN: 1883-1958            Impact factor:   4.642


  3 in total

1.  Comparative Study Clarifying the Most Suitable Material to Be Used as Partial Denture Clasps.

Authors:  Sherif Aly Sadek; Wessam Mohamed Dehis; Hala Hassan
Journal:  Open Access Maced J Med Sci       Date:  2018-06-07

2.  Comparison between Integrated and Parallel Interlock Designs of an Extracoronal Attachment-retained Distal Extension Removable Partial Dentures: A Clinical Trial.

Authors:  Maria R Reslan; Essam Osman; Lucette Segaan; Mohammad Rayyan; Christelle Joukhadar; Mohamed Fattouh
Journal:  J Int Soc Prev Community Dent       Date:  2021-01-30

3.  Shot peening increases resistance to cyclic fatigue fracture of endodontic files.

Authors:  Javier Nino-Barrera; Jose Sanchez-Aleman; Manuel Acosta-Humanez; Luis Gamboa-Martinez; Carlos Cortes-Rodriguez
Journal:  Sci Rep       Date:  2021-06-21       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.